Instruction Manual

CNC programming
Data fields
Q field
3
3.5
3.5.2
l
189
EDSTCXN EN 2.0
Index Meaning Sync Unit
1060 This is set when a probing has happened. It can be used
in the probe cycle as a condition for a modal branch
(G130)
−−−
1061 Number of error triggered for diagnosis purposes −−−
1062 Probe path, reserved for probe cycle mm *
1063 Probe path tolerance, reserved for probe cycle mm *
1064 Probe speed, reserved for probe cycle mm/min *
1065 Deceleration ramp to stop the traverse movement after
a probe
m/s
2
*
1066 Rectraction speed after probing mm/min *
1067 Rectraction acceleration after probing m/s
2
*
1068 Rectraction path relative to the probing position mm *
1069 Waiting time after probing triggering for filtering out
triggered errors
ms
1070 Probe status
0: no probing taken place yet
1: valid probing taking place
2: probing could be valid, decision in the next GIT
1071 ... 1086 Saved probing positions. For the pos. edge these are
accepted at the trigger signal.
mm *
3.5.2 Q field
The Q field is a bit−oriented field with a size of 64 bits. The Q field can be used
to control the progress of a NC program (e.g. G150) by means of external
events. The individual bits can be controlled by the PLC in data block 1. The
assignment can be freely defined by the user.
If fast inputs are configured (see MC and NC software manual), the
corresponding Q bits are not read from data block 1 of the PLC, but rather
directly from the corresponding inputs.
Rectraction handler for
measurement machine