Manual
25
CMVLC401A
Commissioning
9.3 Terminal and Protection Status (P530)
When a read command is issued over the LECOM network to Programming Parameter P530 (code number 1530), the
Terminal and Protection Status data returned can be interpreted as follows:
Data Low Byte
0 TB-13D Input Status
Data High Byte
8 TB-13C Input Status
1 reserved 9 TB-14 Output Status
2 Protection Status 10 Relay Output Status
3 Fast Current Limit Status 11 Charge Relay State
4 Input TB-1 Status 12 Assertion Level Switch State
5 reserved 13 reserved
6 TB-13A Input Status 14 reserved
7 TB-13B Input Status 15 reserved
9.4 Keypad Status (P531)
When a read command is issued over the LECOM network to Programming Parameter P531 (code number 1531), the
Keypad Status data returned can be interpreted as follows:
Data Low Byte
LOCAL Drive Keypad
0 UP Push-button State
Data High Byte
REMOTE Keypad
8 UP Push-button State
1 DOWN Push-button State 9 DOWN Push-button State
2 MODE Push-button State 10 MODE Push-button State
3 FWD/REV Push-button State 11 FWD/REV Push-button State
4
STOP
STOP Push-button State 12
STOP
STOP Push-button State
5
RUN
START Push-button State 13
RUN
START Push-button State
6
CTRL
CTRL Push-button 14
CTRL
CTRL Push-button
7 Unused 15 Unused