User manual

Problem and alarm code Possible cause and solution
The appliance does not drain the wa‐
ter.
The end indicator flashes 2 times
intermittently.
The Start indicator flashes continu‐
ously.
Make sure that the sink spigot is not clogged.
Make sure that the drain hose has no kinks or
bends.
The anti-flood device is on.
The end indicator flashes 3 times
intermittently.
The Start indicator flashes continu‐
ously.
Close the water tap and contact an Authorised
Service Centre.
The appliance stops and starts more
times during operation.
It is normal. It provides optimal cleaning results
and energy savings.
Small leak from the appliance door. The appliance is not levelled. Loosen or tighten
the adjustable feet (if applicable).
The appliance door is not centred on the tub.
Adjust the rear foot (if applicable).
The appliance door is difficult to close. The appliance is not levelled. Loosen or tighten
the adjustable feet (if applicable).
Parts of the tableware are protruding from the
baskets.
Rattling/knocking sounds from inside
the appliance.
The tableware is not properly arranged in the
baskets. Refer to basket loading leaflet.
Make sure that the spray arms can rotate freely.
The appliance trips the circuit-beaker. The amperage is insufficient to supply simulta‐
neously all the appliances in use. Check the
socket amperage and the capacity of the meter
or turn off one of the appliances in use.
Internal electrical fault of the appliance. Contact
an Authorised Service Centre.
Refer to "Before first use",
"Daily use", or "Hints and
tips" for other possible causes.
Once you have checked the appliance,
press Start. If the problem occurs again,
contact an Authorised Service Centre.
For alarm codes not described in the
table, contact an Authorised Service
Centre.
Leonard 53