Submittal Sheet
LEONARD
THERMOSTATIC
H
LEONARD
THERMOSTATIC
C
H
C
Submittal S-1214-LF
November, 2018
1360 Elmwood Avenue, Cranston, RI 02910 USA
Phone: 401.461.1200 Fax: 401.941.5310
Email: info@leonardvalve.com
Web Site: http://www.leonardvalve.com
Engineer's Approval Job # ________________
Arch/Eng. ____________
Contractor ____________
© 2018 Leonard Valve Company
Printed in USA
ALTERNATE
TEMPERATURE
THERMOSTATIC
MIXING VALVES
TYPE TM-AT
____TM-50-AT-LF
____TM-80-AT-LF
____TM-150-AT-LF
____TM-200-SW-AT-LF
__TM-50-AT-LF
Thermostatic water mixing valve
Dura-trol
®
solid bimetal thermostat directly linked to valve porting to
control the intake of hot and cold water and compensate for supply
temperature or pressure fluctuations. Dura-trol
®
is highly responsive
and cannot be damaged by extremes in temperature.
¾” inlets, and 1” outlet
8 GPM (30 l/m) minimum flow capacity, see flow capacity chart.
Internal parts of bronze, brass, and stainless steel
Integral wall support, cast lever handle, combination checkstops.
Color-coded dial, HOT-COLD with directional indicators
Maximum operating pressure 125 PSI (860 KPA)
Adjustable high temperature limit stop set by installer
Outlet temperature full range from 42ºF to 200°F depending upon
incoming Hot and Cold water temperatures
__TM-80-AT-LF
1” inlets and 1 ¼” outlet
13 GPM (49 l/m) minimum flow capacity
__TM-150-AT-LF
1 ¼” inlets and 1 ½” outlet
18 GPM (68 l/m) minimum flow capacity
__TM-200-SW-AT-LF
2” sweat inlets and sweat outlet, inlet checks shipped loose
30 GPM (114 l/m) minimum flow capacity
Note: No CP option
OPTIONS
__SUFFIX LWS - Less Wall support
__SUFFIXTC–Test connection
__SUFFIX CP- Chrome plated, Except for TM-200SW-AT-LF
CAUTION! All thermostatic water mixing valves have limitations. They
will NOT provide the desired accuracy outside of their flow capacity range.
Consult the Flow Capacity Chart and DO NOT OVERSIZE. Minimum
flow must be no less than as indicated.
TM-50-150-AT-LF
TM-200-SW-AT-LF
Note: The operating outlet temperature range of these
valves is outside the normal operating range of a Domestic
Hot Water Distribution Valve and therefore they are
more suitable for Process Temperature Control
applications. Please see Leonard’s complete line of ASSE
1017 Certified Valves for Domestic Hot Water
Applications.
NOTE: Valve is not to be used for domestic hot water distribution. Please
see Leonard Valves complete line of ASSE 1017 certified mixing valves for
Domestic hot water.
Valve assembly meets Low-Lead requirements of wetted
surface area containing less than 0.25% lead by weight.
All other fittings and components, the sum total of which
comprise the wetted surface of this product contains less
than one quarter of one percent of lead by weight.
ECO-MIX
™
NOTE: TM-200 SWEAT INLETS AND OUTLET
(CHECKS SHIPPED LOOSE)
WARNING: This product can expose you to
chemicals including lead, which is known to the
State of California to cause cancer. For more
information, go to www.P65Warnings.Ca.gov
!