Datasheet
HT3C…XL… - 01 2016/06
Technical data
Optical data
Typ. scanning range limit
1)
1) Typ. scan. range limit: max. achievable scanning range for light objects (white 90%)
5 … 100mm
Scanning range
2)
2) Scanning range: recommended scanning range for objects with different diffuse reflection
See tables
Adjustment range 20 … 100mm
Black/white error < 10% up to 60mm
Light spot approx. 3 x 40mm
2
at 50mm
Light source
3)
3) Average life expectancy 100,000h at an ambient temperature of 25°C
LED (modulated light)
Wavelength 633nm (visible red light)
Timing
Switching frequency 1,000Hz
Response time 0.5?ms
4)
4) For short decay times, an ohmic load of approx. 5kOhm is recommended
Response jitter 166μs
Readiness delay 300ms (acc. to. IEC 60947-5-2)
Electrical data
Operating voltage U
B
5)
5) For UL applications: use is permitted exclusively in Class 2 circuits according to NEC
10 … 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 15mA
Switching output see part number code on page 3
Function light/dark switching, see part number code on page 3
Signal voltage high/low (U
B
-2V)/ 2V
Output current max. 100mA
6)
6) Sum of the output currents for both outputs, 50mA for ambient temperatures > 40°C
Scanning range adjustable via 8-turn potentiometer
Indicators
Green LED ready
Yellow LED object detected - reflection
Mechanical data
Housing plastic (high-strength PC-ABS);
2x diecast zinc mounting sleeves or
2x M3 brass threaded sleeves
Optics cover plastic (PMMA)
Weight with connector: 10g
with 200mm cable and connector: 20g
with 2m cable: 50g
Connection type cable 2m (cross section 4x0.20mm²),
connector M8, metal,
cable 0.2m with connector M8 or M12
Environmental data
Ambient temp. (operation/storage) -40°C … +60°C/-40°C … +70°C
Protective circuit
7)
7) 2=polarity reversal protection, 3=short circuit protection for all transistor outputs
2, 3
VDE safety class III
Degree of protection IP 67 IP 69K
Light source exempt group (in acc. with EN 62471)
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 no.14-13
5) 8)
8) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Tables
15 50 100
25 45 90
35 40 80
1 white 90%
2 gray 18 %
3 black 6 %
Scanning range [mm]
Typ. scanning range limit [mm]
Diagrams
A white 90%
B gray 18%
C black 6%
-25
-20
-15
-10
-5
0
5
10
15
20
25
0204060 80100
120
y2
y1
Distance x [mm]
Misalignment y [mm]
Typ. response behavior (white 90%)
y2
x
y1
-4
4
8
12
16
20
24
0
0
20 40 60 80 100 120 140 160
180
A
B
C
Scanning range x [mm]
Red. of scan range y [mm]
Typ. black/white behavior
x
y
Notes
Observe intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
HT3C XL