Datasheet

HT46C… - 01 2015/06
Specifications
Optical data
Typ. scanning range limit (white 90%)
1)
1) Typ. scan. range limit: max. achievable scanning range for light objects (white 90%)
5 3000mm
Scanning range
2)
2) Scanning range: recommended scanning range for objects with different diffuse reflection
see diagrams
Black-white error <10% up to 1200mm
Scanning range adjustment mechanical adjusting spindle
Adjustment range 120 3000mm
Light source LED (modulated light)
Wavelength 630nm (visible red light)
Timing
Switching frequency 250Hz
Response time 2ms
Delay before start-up 300ms
Electrical data
Operating voltage U
B
3)
3) For UL applications: for use in class 2 circuits only
10 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 20mA
Switching outputs/functions
4)
/4P
4) See part number code
2 PNP switching outputs, antivalent
/4X 1 PNP switching output, light switching
/4W 1 PNP switching output, light switching, 1 PNP warning
output
/48 1 PNP switching output, light switching, 1 activation input
/PX 1 PNP switching output, dark switching
/2N 2 NPN switching outputs, antivalent
Signal voltage high/low (U
B
-2V)/ 2V
Output current max. 100mA
Indicators
Green LED ready
Yellow LED reflection
Yellow LED, flashing reflection, no performance reserve
Mechanical data
Housing plastic
Optics cover plastic
Weight with M12 connector: approx. 60g
with 200mm cable and M12 connector: approx. 65g
with 2000mm cable: approx.100g
Connection type M12 connector, 4-pin
cable 200mm with M12 connector, 4-pin
cable 2000mm, 4 x 0.21mm²
Environmental data
Ambient temp. (operation/storage) -40°C +60°C/-40°C +70°C
Protective circuit
5)
5) 2=polarity reversal protection, 3=short circuit protection for all transistor outputs
2, 3
VDE safety class
6)
6) Rating voltage 50V
II, all-insulated
Protection class IP 67, IP 69K
Light source exempt group (in acc. with EN 62471)
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14-13
4)
7)
7) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Options
Warning output PNP transistor, counting principle
Signal voltage high/low (U
B
-2V)/ 2V
Output current max. 100mA
Activation input
Transmitter active/not active 8V/ 2V
Activation/disable delay 1ms/ 2ms
Input resistance 10K ±10%
Tables
1 5 3000
2 20 2000
3 50 1500
1 white 90%
2 gray 18%
3 black 6 %
Scanning range [mm]
Diagrams
A white 90%
B gray 18%
C black 6%
-15
-12
-9
-6
-3
0
3
6
9
12
15
0 200 400 600 800 1000 1200
y2
y1
Distance x [mm]
Misalignment y [mm]
Typ. response behavior (white 90%)
y2
x
y1
0
200
400
600
800
1000
0 500 1000 1500 2000 2500 3000
A
B
C
Scanning range x [mm]
Red. of scan range y [mm]
Typ. black/white behavior
x
y
Remarks
Operate in accordance with
intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with the intended use.
HT46C