Datasheet

L49C…-TB - 01 2016/06
L49CI…-TB - 01
Technical data
Optical data L49C… L49CI…
Typ. operating range limit
1)
1) Typ. operating range limit: max. attainable range without function reserve
0…150m
Operating range
2)
2) Operating range: recommended range with function reserve
0.5 120m
Light source
3)
3) Average life expectancy 100,000 h at an ambient temperature of 25°C
LED (modulated light)
Wavelength 630nm (red light) 860nm (infrared light)
Timing
Switching frequency 500Hz
Response time 1ms
Readiness delay 300ms
Electrical data
Operating voltage U
B
4)
4) For UL applications: for use in class 2 circuits only
10 30VDC (incl. residual ripple)
Residual ripple 15% of U
B
Open-circuit current 20mA
Switching outputs/functions
5)
/4P
5) See part number code
2 PNP switching outputs, antivalent
/4W 1 PNP switching output, light switching, 1 PNP warning
output
/4X 1 PNP switching output, light switching
/PX 1 PNP switching output, dark switching
/2N 2 NPN switching outputs, antivalent
Signal voltage high/low (U
B
-2V)/ 2V
Output current Max. 100mA
Sensitivity/operating range adjustment 225° potentiometer (only LE49C[I].1…)
Indicators
Green LED Ready
Yellow LED Light path free
Yellow LED, flashing Light path free, no function reserve
Yellow LED (behind lens cover) Transmitter: active/not active
Receiver: signal/no signal
Yellow LED (behind lens cover), flashing Receiver: signal, function reserve limited
Mechanical data
Housing Polycarbonate
Optics cover Plastic
Weight 150g
Connection type Spring terminals, max. wire cross section 1.5mm
2
Environmental data
Ambient temp. (operation/storage) -40°C +6C/-4C +7C
Protective circuit
6)
6) 1=transient protection, 2=polarity reversal protection, 3=short circuit protection for all outputs
1, 2, 3
VDE safety class
7)
7) Rating voltage 50V
II, all-insulated
Degree of protection IP 67, IP 69K
8)
8) IP 69K test acc. to DIN 40050 part 9 simulated, high pressure cleaning conditions without the use of additives,
acids and bases are not part of the test
Light source Exempt group (in acc. with EN 62471)
Standards applied IEC 60947-5-2
Certifications UL 508, CSA C22.2 No.14-13
4)
9)
9) These proximity switches shall be used with UL Listed Cable assemblies rated 30V, 0.5A min,
in the field installation, or equivalent (categories: CYJV/CYJV7 or PVVA/PVVA7)
Additional functions
Switching function (teach level 1) Light switching (factory setting) or dark switching
Time module (teach level 2) Active: dropout delay 500ms
Not active:no dropout delay (factory setting)
Warning output PNP transistor, counting principle
Signal voltage high/low (U
B
-2V)/ 2V
Output current Max. 100mA
Activation input
Transmitter active/not active 8V/ 2V
Activation/disable delay 1ms
Input resistance 10k ±10%
Tables
0/0,5 120 150
Operating range [m]
Typ. operating range limit [m]
Notes
A light axis consists of a
transmitter and a receiver
with the following
designations:
L49C[I]… = light axis, complete
LS49C[I]…= transmitter
LE49C[I]… = receiver
Alignment indicator:
(’K’ see dimensioned
drawing)
Yellow LED =
light path free - with
reserve
Yellow LED, flashing =
light path free - no func-
tion reserve
Observe intended use!
This product is not a safety sensor
and is not intended as personnel
protection.
The product may only be put into
operation by competent persons.
Only use the product in accor-
dance with its intended use.
L49C
Diagrams
L49C… with red light
L49CI… with infrared light
-3,5
-1,0
-0,5
0,5
0
1,0
1,5
0 50 100 150 200 250
y1
y2
Distance x [m]
Misalignment y [m]
Typ. response behavior
-3,5
-1,0
-0,5
0,5
0
1,0
1,5
0 50 100 150 200 250
y1
y2
Distance x [m]
Misalignment y [m]
Typ. response behavior
y2
y1
x