Datasheet

L49C…-TB - 01 2016/06
L49CI…-TB - 01
Teach procedure for sensor
Note
Factory setting: light switching,
time module not active
Light/dark switching
Adjusting the switching behavior
Activation/deactivation of the time module
Setting a slow release
Dropout delay: if the object is no longer present, the output switches with a time delay.
Teach level 1
Teach level 2
Press teach button (2 to 7s) until both LEDs (green/yellow) flash synchronously.
Release teach button – switchover is complete.
The yellow LED then indicates the current setting of the switching output for 3s:
ON = light switching = output OUT1 (terminal 3) light switching
output OUT2 (terminal 4) dark switching
OFF = dark switching = output OUT1 (terminal 3) dark switching
output OUT2 (terminal 4) light switching
2…7s
Press teach button (7 to 12s) until both LEDs (green/yellow) flash alternately.
Release teach button – activation/deactivation is complete.
The yellow LED then indicates the current setting of the dropout delay for 3s:
ON = time module not active = no dropout delay
OFF = time module active = dropout delay: 500ms
1)
1) Additional models on request
7…12s