Functions configurable via IO-Link
PC configuration and visualization is performed comfortably with the USB-IO-Link Master SET US2-IL1.1 (part no. 50121098) and
the Leuze Sensor Studio (in the download area of the sensor at www.leuze.com
).
Function block Function Description
Configuration
Logical function of Q2
If the function Q2 = switching output is selected, the switching function corresponds to
the current setting which was selected via the L/D changeover.
If Q2 = inv. switching output is selected, the switching behavior of the output is inverted.
Key Lock On disables the teach button on the sensor.
L/D switching
In the factory setting, outputs Q1 and Q2 are antivalent switching outputs:
Light switching: Q1 = light switching, Q2 = dark switching.
Dark switching: Q1 = dark switching, Q2 = light switching.
Switching delay On activates the internal time function.
Function selection of the
switching delay
Activation of a suitable switching delay is possible. It is not possible to combine switching
delays.
Time base of the switch-
ing delay
Possibility of selecting a time base.
Factor for the time base of
the switching delay
To adapt the time base, it is multiplied by the entered factor. Only whole-number factors
from 1 to 15 are permitted.
Function block Function Description
Commands
(The commands with a
gray background cor-
respond to the func-
tions which can be
performed at the sen-
sor using the teach
button or the remote
teach function.)
Sensitive teach
for the detection of a transparent object (e.g. empty single
bottle)
Clear the light path before activation.
Standard teach
for the detection of a partially transparent object (e.g. bottle
made of colored glass)
Clear the light path before activation.
Light switching
Dark switching
Switch the process data display mode to analog value
Activate to display diagrams on the Process tab when
using Leuze Sensor Studio.
PRK3C autocollimation