Datasheet
PRK3CL Laser - 02 2017/02
IO-Link interface
Sensors in the PRK3C…/L… variant have a dual-channel architecture. The IO-Link interface in accordance with specification
1.1.1 (October 2011) is provided on pin 4 (OUT 1). This allows the devices to be configured quickly and easily and, therefore,
cost-effectively. Furthermore, the sensor transmits its process data and makes diagnostic information available through it.
Parallel to the IO-Link communication, the sensor can output the continuous switching signal for object detection on OUT 2. The
IO-Link communication does not interrupt this signal.
Note: In Leuze Sensor Studio, the following applies with regard to the designations: Q1 = OUT 1, Q2 = OUT 2.
IO-Link process data
Output data device
Input data device
Device-specific IODD
At www.leuze.com in the download area for IO-Link sensors you will find the IODD zip file with all data required for the installa-
tion.
IO-Link parameter documentation
A complete description of the IO-Link parameters is given in the *.html files. Please double-click one of the two language variants:
*IODD*-de.html for German or *IODD*-en.html for English.
Data bit Assignment Meaning
76543210
Switching output Q1 (OUT 1) 0 = inactive, 1 = active
Warning output autoControl 0 = no warning, 1 = warning
Sensor operation
1)
1) Sensor operation off when detection is not possible (e.g during the teach event)
0 = off, 1 = on
Not used Free
Not used Free
Not used Free
Not used Free
Not used Free
Data bit Assignment Meaning
76543210
Deactivation 0 = transmitter active,
1 = transmitter inactive
Not used Free
Not used Free
Not used Free
Not used Free
Not used Free
Not used Free
Not used Free
PRK3CL autocollimation