FCS-0071 User’s Manual FCS-0071 2-Megapixel Fish-Eye PoE Network Camera User’s Manual Version: 1.
FCS-0071 User’s Manual Contents General Public License ...................................................................................................................................2 Notices ...........................................................................................................................................................3 Introduction .................................................................................................................................................
FCS-0071 User’s Manual General Public License This product incorporates open source code into the software and therefore falls under the guidelines governed by the General Public License (GPL) agreement. Adhering to the GPL requirements, the open source code and open source license for the source code are available for free download at http://global.level1.com.
FCS-0071 User’s Manual Notices This user manual is intended for administrators and users of the FCS-0071 Network Camera, including instructions for using and managing the camera on your network. The use of surveillance devices may be prohibited by law in your country. It is the user’s responsibility to ensure that the operation of such devices is legal before installing this unit for its intended use.
FCS-0071 User’s Manual Introduction FCS-0071 is a 2 Mega Pixel Fish-Eye Panorama Network Camera with H.264-AVC performance and other rich functions. FCS-0071 is equipped with a fish-eye lens for 360° panoramic wide angle view without blind spots making it the perfect solution for viewing wide areas with like hallways, stores, and offices without the need to install multiple cameras. H.
FCS-0071 User’s Manual Installation FCS-0071 – Physical Overview 5 5
FCS-0071 User’s Manual Terminal block for I/O connectors 6 Pin Function Description 1 DO_NO 2 DO_COM Digital output implementation; Pin7 to COM (Pin6) is a Photo-coupled relay on Normal Open status. External device can directly connect to the terminals. However the current that will go through the 2 nodes must not exceed 130mA. An external “Relay” can also be connected to the terminals as an implementation. In this case, current (or/and voltage) limitation is specified by the external Relay.
FCS-0071 User’s Manual 1. Hardware Connection 1. 2. 3. 4. Prepare a PC with Ethernet link to the network Connect LAN port (RJ45) of the camera to a network switch/hub Connect power jack (ignore if using PoE) Ensure the power adaptor specification matches the power system (110V or 220V) and connect the adaptor to the outlet 5.
FCS-0071 User’s Manual 2. Software Installation The following software is necessary for the proper display and use of the FCS-0071 from the Web site. The software will be taken from the Software Package CD. IP Installer The IP Installer is used to locate and configure network cameras and video servers on the LAN. This utility is useful for conveniently configuring the network settings of the device, or for finding a device once the network settings have been modified.
FCS-0071 User’s Manual 3. Network Configuration IP Installer is a utility that provides an easier, more efficient way to configure the IP address and network settings of the devices. It even provides a convenient way to set the network settings for multiple devices simultaneously using the batch setting function. Moreover, IP Installer can save the network settings for all devices as a backup and restore them when necessary. Preparation before IP Assignment 1. 2. 3. 4.
FCS-0071 User’s Manual 4. Double click the select item to open the Property Page or right click the item to select the [Single Device Setting]. 5. Modify the network settings of the camera. 10 6. After filling in the properties, click [Set] button to complete the configuration settings.
FCS-0071 User’s Manual 7. Click the [Batch Device Setting] to set several devices.
FCS-0071 User’s Manual 8. Language support for Chinese, English and Spanish.
FCS-0071 User’s Manual Open the Web-based UI of the selected camera 1. To access the Web-based UI of the selected unit, run the Open Web on the select item. 2. For first time user, there will be a prompt to install the ActiveX control. Confirm the installation as it is required to view the video stream and some operations. 13 3. If the device has been configured correctly, the default Web browser will open to the home page of the selected device.
FCS-0071 User’s Manual Verify and Complete the Installation from Your Browser When browsing the Home Page at the first time with the Microsoft Internet Explorer TM, you must temporarily lower your security settings to perform a one-time-only installation of the ActiveX component onto your workstation, as described below: 1. From the Tools menu, select [Internet Options] 2. Click the [Security] tab and then click [Custom Level] button to see your current security settings. 3.
FCS-0071 User’s Manual Using the Web UI Start your Web browser and enter the URL or IP address in the Address field. The Home page of the camera is now displayed.
FCS-0071 User’s Manual 1. Live View Video format IP address of the camera Button Bit rate Resolution Frame Rate Description 16 Click for more general/advance camera settings Select languages among English, traditional Chinese and simplify Chinese Select display mode to view the different type of the video layout.
FCS-0071 User’s Manual Button Description Full screen Listen the audio input from local end 17 Talk function Record instant live video Snapshot the image 17
FCS-0071 User’s Manual Configuration Pages List Video General Advance Camera General Advance Event Event Server Motion Detection I/O ports Event Configuration Schedule General Storage Network General Advance SMTP (E-mail) DDNS 18 System Information User Date & Time Server Maintenance Log Service Customize Style Layout 18
FCS-0071 User’s Manual 2. Video General OSD Setting: Enable OSD to display camera name and date/time on the image. A line of text message (e.g. Camera Name or Position) and the date/time string are available to be selected for displaying or hiding on the images. The PTZ function will display in Quad with source view, Double with source view , Double view and Triple view of Wall and Wall 720P Mount. Click on the PTZ icon, the web will popup the control panel to control e-PTZ function of FCS-0071.
FCS-0071 User’s Manual Double with source view PTZ control panel: 1 3 4 2 5 6 20 1. Step: Setting the speed of Pan function. (1~10) 2. Pan Arrow: Click to control Pan function. 3. Move the control panel. 4. Close the control panel. 5. Zoom: Digital zoom in/out.(1~10) 6. List of preset points.
FCS-0071 User’s Manual Triple & Quad with source & Double view PTZ control panel: 1 2 5 6 3 4 7 21 1. Ch:Select the channel. (1~4) & (2~4) 2. Step:Setting the speed of Pan/Tilt function. (1~10) 3. Pan Tilt Arrow:Click to control Pan/Tilt function. 4. Zoom:Digital zoom in/out. (1~10) 5. Move the control panel. 6. Close the control panel. 7. List of preset points.
FCS-0071 User’s Manual Advanced 22 Stream 1 Setting: RTSP Path: It is the stream ID used for RTSP client streaming connection, such as VLC player. (default v00) Resolution: 1600x1200, 800x600, 640x480. Video Mode: Choose between variable bit rate (VBR) and constant bit rate (CBR) VBR-> Choose quality level from best to standard, for some environment it is very important to ensure the video quality level but after selecting video quality level, the bandwidth consumption will be variable.
FCS-0071 User’s Manual 3.
FCS-0071 User’s Manual Camera General Setting: Brightness: the luminance of image view. Hue: refer to pure color, it can modify the different display of specific color such as red, green or blue. Saturation: intensity of a specific color. The 3 correlates are referring image appearance in terms of color/vision. These are adjustable from this page. Contrast: the difference in color and light between parts of an image. Sharpness: the sharpness of camera.
FCS-0071 User’s Manual Advanced 25 White balance: Adjustment to compensate for different environments in terms of light source. Exposure: Anti-flicker setting for image sensor to fit the frequency of light (power) source. For instance, the power frequency is 50Hz for most European countries, while 60Hz is typically for US. This setting is therefore regionally different.
FCS-0071 User’s Manual Max Exposure Time: Referring to the shutter speed. Max Gain Control: The amplification factor for the incoming light. Infrared (IR) Cut Filter: The default is automatically switched according to light intensity. Enable indicate the filter is enable to cut IR light to make sure the color is correct, Disable indicate the filter is disable and allow the infrared (such as IR LED illuminator) to enter the camera to execute low lux surveillance application.
FCS-0071 User’s Manual 2. Broad view: 3. Quad with source view: 4. Triple view: 27 Ceiling Mount: Choose Ceiling mount, Go back to live view, there are 2 kinds of video layout to choose from; Original view, Quad view. 1.
FCS-0071 User’s Manual 2. Quad view: 28 Wall 720P Mount: Choose Wall 720P mount type, Go back to Live view, there are 3 kinds of n video layout to choose including Broad view、Double view、Double with source view 1.
FCS-0071 User’s Manual 2. Double view: 29 3.
FCS-0071 User’s Manual 4. Event Event Server 30 Click on the [Add FTP] to expand FTP server setting. FTP Server: Name: Give a name for the FTP server Network Address: Input the network address of the FTP server Upload Path: Choose the desired upload path for events Port: Input the port number of the FTP server Login Information: Username / Password: Input the username and password of the FTP Click on the [Add HTTP] to expand HTTP server setting.
FCS-0071 User’s Manual Motion Detection 31 1 To add a motion detection area: 1. Click on [Add] to set up a detection area.
FCS-0071 User’s Manual 2 3 4 2. Give a name to this window area. 3. Select the trigger level and sensitivity for this detection window. (0~100, low~high) 4. Select color for detection window. 32 5. Draw detection window on the image.
FCS-0071 User’s Manual 6. Once everything is done, click on [Save] to save the configuration made. Configured detection window will be displayed in motion detection list. (Circled in blue) Note: 1. Maximum number of detection window is 10. 2. Motion Detection windows need to be modified if users changed video layout. I/O Ports 33 This model supports 1 photo-coupled relay inputs and 1 relay outputs, see “I/O Terminal Connectors” for detail pin description and application.
FCS-0071 User’s Manual Event Configuration The Event Configuration is to assign the actions responding to the specified events (Trigger Conditions). The table lists the configured events. Click on “Add…” or choose an event from the list to expend the panel for detail configurations. “Remove” is to delete a selected event 1 2 3 4 34 5 6 1. To add an event trigger, click on [Add] and setup panel will be expanded. 2. Give a name to this event. 3. Set the time interval between each trigger. 4.
FCS-0071 User’s Manual “Send Email Notification” and “Send HTTP Notification to” and “Send Message Notification (TCP)”. 6. Click on [Save] to save the configuration made.
FCS-0071 User’s Manual 5. Schedule General Define the day (specified by days of a week) and time (specified by each single hour) for that will be recording during the scheduled period. Note that only video data will be recorded. User can select which video stream should be recorded, and the size of each sliced file. When the check box is ticked and setting is saved, recording process starts. Recording files are saved to the Micro SD storage.
FCS-0071 User’s Manual Storage Display the storage information, includes disk size info, type and status. The warning message shows when recording is on process; Micro SD card should not be removed during the recording process. 37 The “Browse” button allows viewing the list of recorded files. The web page will then be redirect to the root path of the SD storage (if one is inserted).
FCS-0071 User’s Manual 6. Network General Device IP configuration, includes DHCP and Static IP setting. “Enable ARP/Ping” enable device to accept ARP or ping packets from the network. Disable this option may provide extra security from intentional ping.
FCS-0071 User’s Manual Advanced Enable or configure other network functions. 39 NTP: Configure a NTP (Network Time Protocol) server, so that the device system date and time can be synchronized with a specified Time Server or DHCP server. HTTP: set the HTTP port that will be applied for Web UI access. RTSP: set the RTSP (Video) port for video data transmission. Bonjour: Enable Bonjour service, so that the device can be discovered with “Bonjour” service applied.
FCS-0071 User’s Manual SMTP (E-Mail) Configure an email host in the device that will send email on behalf of the configured email account in a circumstance like sending an email notice to a specified mail address (Event Configuration). Complete the Mail Server, Server Port, Authentication information (if required) and the sender email address.
FCS-0071 User’s Manual DDNS Dynamic DNS configuration; the network device can be assigned with a host name by registering this service (Internet access required). Host Name: Assigned name that will be used for access to the device User Name/Password: Account authentication for logging to this service Update Time: Periodically, the device updates its access info to sever in the configured time. Response: the device responds the connection info.
FCS-0071 User’s Manual 7.
FCS-0071 User’s Manual User Login users for Web access and operations; authentication required. The Check box is for anonymous logging on to the live view page. Logging for further configurations will still require user name and password.
FCS-0071 User’s Manual Date & Time System date/time configuration. Options of synchronizing with PC and NTP server are provided for automatic adjustment.
FCS-0071 User’s Manual Server Maintenance This page provides tool for system maintenance; Reboot and Load default settings, as well as functionalities of launching upgrade process, backup/restore user settings and language defines.
FCS-0071 User’s Manual Log Service Most system operations and / or process will be kept in a log system. The link provides the review of these records.
FCS-0071 User’s Manual 8. Customize This page provides the function of adjusting the look of live view page. There are two types of layout settings; use default look or use custom settings. 47 Use Default Look: the default layout of live/configuration pages. Use Defined Links: Web link(s) will be presented on the live page when enabled. It can be a link to another IP camera for instance, or other preferred web link.
FCS-0071 User’s Manual Use Custom Settings: The modifications allowed are change of Background / Text Color, Background picture, Title, Description, Logo and etc.
FCS-0071 User’s Manual FAQ Restore Factory Default In some cases, system does not respond to any operation, this process gets the unit back to initial status, so that it can be reconfigurable for up and running again. To restore factory default, please follow the steps: 1. 2. 3. 4. Unplug the power jack to turn off the camera Insert a pin into the reset hole pressed the reset button and keep it pressed until instructed to release. Plug in the power jack to turn on the camera.
FCS-0071 User’s Manual then click on “Upgrade” button. 5. The upgrade should start in minutes, depending on file transferring status. The web will then be directed to the system writing progress. Overall upgrading process takes about 5~10 minutes. In this period, DO NOT DISCONECT the power. System of the unit can be damaged otherwise. 50 6. The power LED (orange one) will be quick/slow flashing during the upgrading process. When it becomes again steady on, camera is ready to be accessed.