User's Manual

PRELIMINARY
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For details
visit www.leviton.com or call 1-800-824-3005. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating
conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose,
is limited to five years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
ADVANCED PROGRAMMING FEATURES
Definition of A Modes
A-1)
N/A
A-2)
Maximum Fan Speed: Sets the maximum fan speed level.
A-3)
Minimum Fan Speed: Sets the minimum fan speed level.
A-4)
Preset ON Level: Sets the turn on fan speed level regardless of
the previous set fan speed level.
Definition of B Modes
B-1)
N/A
B-2)
N/A
B-3)
LED Options: Sets the time period in seconds the Locator LED
and Brightness display will stay on before extinguishing.
B-3)
The Locator LED will blink 3 times per second to indicate Program
Mode B-3, LED Options. To change the LED Options settings, use
the Fan Speed Bar to move the LED to the desired preset setting
according to the LED Options Chart. By tapping the Top of the
Rocker this setting will automatically be saved and the device will exit
Programming Mode B.
Program Mode A
To enter Program Mode A:
Press and hold the TOP of the Rocker and the TOP of the DIM/BRIGHT
Bar simultaneously for 5 seconds until the Locator LED begins to blink.
LED 7
Fan
Speed
Bar
Locator LED
LED 1
Definition of LEDs
Bottom LED = LED 1
Top LED = LED 7
NOTES:
The device will exit programming
mode after 3 minutes of inactivity.
Pressing the TOP of the Rocker at
any time during programming will
advance the device to the next
programming mode.
Fan Speed Bar
INCREASE:
Press the TOP half of the Fan Speed Bar – Fan speed increases to
desired level.
DECREASE:
Press the BOTTOM half of the
Fan Speed Bar
Fan speed decreases
to desired level.
If you continue to hold, the fan speed level decreases to
the minimum level and then turns OFF.
NOTE: When the fan is OFF you can change the fan speed level that
the fan will turn ON to using the Fan Speed Bar. If there is a power
outage, when the power is restored, the fan speed will return to the last
setting before the power interruption.
NOTE: The locator light will illuminate when
the load is in the OFF position to facilitate
access in the dark.
NOTE: If using the fan speed control in a
3-way application, the fan will turn ON at the
speed set on fan speed control bar. The fan
can be controlled from either the fan speed
control, the remote location or the mobile
device app.
Push Pad (Default settings)
Turn ON from OFF position:
Tap TOP of Rocker: Fan turns ON to preset
level.
Turn OFF from ON position:
Tap BOTTOM of Rocker. Fan turns OFF.
OPERATION
LED Brightness
Display
Fan Speed
Bar
Rocker
Locator
Light
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
Gently pull out
from bottom
Air-Gap Switch: On the fan speed control only,
engage the air-gap switch by gently pulling out
from the bottom of the Fan Speed Bar until the
bottom of the bar lifts completely out of the frame
and a click is heard (refer to Figure). LED's will
turn OFF. This will stop power to the fixture. After
servicing is complete, press the Fan Speed Bar
back into place for normal operation.
Download the Leviton Decora
®
Digital Dimmer & Timer App for
your device.
Android: Tap the Google Play Store icon on your phone or go to
http://play.google.com on your computer and follow the
instructions to obtain the app.
iPhone: Tap the App Store icon on your phone or access the app
through your iTunes account on your computer.
Once you have downloaded the app, follow the instructions on the screen
to pair your mobile device with your fan speed control. Once your mobile
device is paired, use the following options to control your fan speed:
On - Off: Turns the fan speed control ON and OFF.
Schedule: Creates distinct ON/OFF events based on time and day.
Sleep Timer: Sets countdown to turn fan speed control OFF.
Advanced Settings
Device Options
Hide LED Dim Bar: Turns LED Dim Bar OFF.
Hide Status LED: Turns Status LED OFF.
DST Offset Hours: Adjusts the Sunrise/Sunset time in hours.
DST Offset Minutes: Adjusts the Sunrise/Sunset time in minutes.
Fan Speed Options
• Preset: Sets the fan speed level at which the fan turns ON.
• Minimum: Sets a minimum fan speed level.
• Maximum: Sets a maximum fan speed level.
DI-000-DDF01-02A-X0
Fan does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Fan is burned out.
- Neutral not wired to Fan Speed Control (White wire).
- Confirm that the device is being supplied from a 120V, 60 Hz AC
source ONLY.
Remote does not operate fan
- Ensure that total wire length does not exceed 300 ft.
- Ensure wiring is correct.
TROUBLESHOOTING
CONTROLLING YOUR FAN SPEED CONTROL WITH
BLUETOOTH
®
Restore power at circuit breaker or fuse.
Press pad until locator light is OFF. Fan
should turn ON. If the fan does not turn
ON, press the TOP half of the Fan Speed
Bar until the fan speed increases.
If the fan still does not turn ON, refer to
the TROUBLESHOOTING section.
Testing your Fan Speed Control prior to
mounting in wall box:
Step 5
Position all wires to provide room
in outlet wall box for device.
Ensure that the word “TOP” is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
NOTE: Dress wires with a bend as
shown in diagram in order to relieve
stress when mounting device.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada
should contact Leviton in writing at Leviton Manufacturing of Canada
Ltd to the attention of the Quality Assurance Department, 165
Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by
telephone at 1-800-405-5320.
Fan Speed Control Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Step 6
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
N
OTE: To pair your fan speed control with your mobile device,
download the Leviton Decora
®
Digital Dimmer and Timer app from the
Google Play Store or your iTunes account. Contact Leviton’s Techline
at 1-800-824-3005 or visit Leviton’s website at www.leviton.com for
additional information.
This device complies with Part 15 of the FCC Rules. Operation is subject to
following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a
Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment OFF
and ON, the user is encouraged to try to correct the interference by one or
more of the following measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modifications not expressly approved by Leviton
Manufacturing Co., Inc., could void the user's authority to operate the
equipment.
FCC COMPLIANCE STATEMENT
Copyright and Trademark Information
The Bluetooth
®
word mark and logos are registered trademarks owned by
Bluetooth SIG, Inc., used under license by Leviton.
Use herein of third party trademarks, service marks, trade names, brand
names and/or product names are for informational purposes only, are/may
be the trademarks of their respective owners; such use is not meant to imply
affiliation, sponsorship, or endorsement.
No part of this document may be reproduced, transmitted or transcribed
without the express written permission of Leviton Manufacturing Co., Inc.
For additional information, contact Leviton’s Techline at
1-800-824-3005 or visit Leviton’s website at www.leviton.com
This product is covered by U.S. Patent No. 8,664,886 and corresponding
foreign patents.
© 2015 Leviton Mfg. Co., Inc.
Program Mode B
To enter Program Mode B:
Press and hold the TOP of the Rocker and then the BOTTOM of the Fan
Speed Bar for 5 seconds until the Locator LED and the TOP LED (LED 7)
begin to blink.
A-2)
Maximum Fan Speed Level: The Locator LED will blink 2 times per
second to indicate the device is in Program Mode A-2, Maximum
Fan Speed Level.The default mode is 100% i.e. full fan speed. To
change the fan speed level, use the Fan Speed Bar to move the
corresponding LED to the desired discreet preset level according to
the Maximum Fan Speed Chart. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to
the next Programming Mode, A-3, Minimum Fan Speed Level.
MAXIMUM FAN SPEED CHART
When indicator is at LED # Fan speed is at
7 Max
5 High
3 Medium
1 Low
LED OPTIONS CHART
LED Locator LED Timeout LED Brightness Display Options
1 Active Active
2 Active Turns OFF 5 seconds after use
3 Turns OFF 5 seconds after use Active
4 Turns OFF 5 seconds after use Turns OFF 5 seconds after use
5 N/A N/A
6 N/A N/A
7 N/A N/A
A-3)
The Locator LED will blink 3 times per second to indicate the device is in
Program Mode A-3, Minimum Fan Speed Level. The default Minimum
fan Speed Level is LED 2. To change the Minimum Fan Speed Level
from 1-50%, use the Fan Speed Bar. The fan speed will reflect the
minimum fan speed level selected. By tapping the TOP of the Rocker
this setting will automatically be saved and the device will advance to the
next programming mode, A-4, Preset ON Level.
A-4)
The Locator LED will blink 4 times per second to indicate Program
Mode A-4, Preset ON Level. To change the current Preset ON
Level from 1-100%, use the Fan Speed Bar. If this feature is not
desired, press and hold the BOTTOM half of the Fan Speed Bar
until no LED is lit (default setting). By tapping the TOP of the Rocker
this setting will automatically be saved and the device will exit
Programming Mode A.
IC COMPLIANCE STATEMENT
This device complies with Industry Canada licence-exempt RSS
standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept
any interference, including interference that may cause undesired
operation of the device.
If your fan speed control is not responding, or you are unable to control
it after you have tried to Pair/Connect to it multiple times, it may be
necessary to reset the fan speed control to its original factory settings.
To accomplish this, proceed as follows:
On the fan speed control, hold the TOP of the rocker until the locator LED
starts to blink. The fan speed control is now reset. Once the fan speed
control is reset, it may be necessary to re-pair with the your application.
FACTORY DEFAULT