User's Manual

PRELIMINARY
Testing your Dimmer prior to mounting in
wall box:
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchase
date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any
manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years.
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Step 5
Restore power at circuit breaker or
fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do not
turn ON, press the upper half of DIM/
BRIGHT bar until the lights brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer
and/or remote.
- Local switch, ON
Light does not turn ON and Locator LED does not
turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
- Confirm that the device is being supplied from a 120V, 60Hz
AC source ONLY.
- Confirm that unit is programmed properly. Repeat “TO INSTALL”
section to verify that it has been included in the Z-Wave™
network.
Intermittent dimmer operation
- Minimum load is under 40W.
- Confirm that the Load being controlled does not exceed the
600W dimmer limit.
Remote does not operate lights
- Ensure that total wire length does not exceed 300 ft.
For additional information, contact Leviton’s Techline
at
1-800-824-3005
or visit Leviton's website at
www.leviton.com
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Position all wires to provide room
in outlet wall box for device.
Ensure that the word "TOP" is
facing up on device strap.
Partially screw in mounting screws
in wall box mounting holes.
Step 6
Including Scene Capable Dimmer into
Z-Wave™ Network:
NOTES:
If using a non-Leviton Programmer/Controller, refer to the
Programmer/Controller instruction sheet for Including a device.
A) If using a Leviton Z-Wave™ Programmer/Controller, Cat. No.
RZCPG, press the Menu button and scroll down to System
Setup. Press the center button to select System Setup Menu.
Press the center button to select Network.
Menu Button
B) While standing close to the module (approx. 2-5 ft), press the
center button to <Include> device in the network.
NOTE: Only one device may be included at a time. DO NOT
put multiple devices into the Inclusion mode at any time.
C) While the Programmer/Controller is in
the Inclusion mode and the Locator
LED is ON on the dimmer, push the
push pad to turn ON the dimmer. The
Programmer/Controller will verify
inclusion and the locator LED will turn
OFF on the dimmer.
If the dimmer is flashing Amber while
in the Inclusion mode, the
Programmer/Controller is still trying to
communicate with the dimmer. Wait
until the device stops flashing,then
press push pad.
NOTE: If the locator LED on the
dimmer turns solid Red while
including, there has been a communication error. Refer to
Troubleshooting section.
D) The Primary Programmer/Controller wil assign a node ID
number (Name) for this module.
NOTE: This ID number (Name) will be stored in the controller
library to be used for future reference.
NOTE: You may name or edit the node of this device at this
time.
E) The dimmer is now installed in the network.
NOTE: If a dimmer has been successfully Included in the network
and the user tries to Include it again without first excluding it from
the network, the module will retain the first node ID it had received
and ignore the second.
Excluding Dimmer from Network:
NOTE: It is very important to accurately Exclude
devices from the network when moving or removing a
device from a Z-Wave™ network. This ensures that all
information has been removed from your Primary
Programmer/Controller’s information table and is not
counted on to be a part of the mesh network.
A) If using a Leviton Z-Wave™ Programmer/Controller, Cat.
No. RZCPG, press the Menu button and scroll down to
NOTE: Remote must be in close proximity to
dimmer when including in the network.
RZCPG
Programmer/Controller
Step 7
System Setup. Press the center button to select System
Setup Menu. Press the center button to select Network.
B) While standing close to the module, press the center
button to <Exclude> device from the network.
C) While the Programmer/Controller is in the Exclusion mode
and the locator LED is ON on the dimmer, press the push
pad on the dimmer. The Programmer/Controller will verify
Exclusion and the locator LED will turn OFF on the dimmer.
If the dimmer is flashing Amber while in the Exlusion mode,
the Programmer/Controller is still trying to communicate
with the dimmer. Wait until the device stops flashing, then
press the push pad.
Factory Default:
If your dimmer is not responding, or you are unable to control it after
you have tried to Include/Exclude it multiple times, it may be
necessary to reset the dimmer to its original factory settings. To
accomplish this, proceed as follows:
On the dimmer, engage he air-gap switch (refer to Operation
section) and wait 5 seconds. Press push pad back into frame
and hold push pad until the locator LED flashes Amber and turns
solid Red. The dimmer is now reset. Once the dimmer
is reset, it will be necessary to Re-Include it to a network before it
can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES
NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE
EXCLUSION PROCEDURE MUST STILL BE FOLLOWED TO
REMOVE THE DEVICE FROM THE PRIMARY CONTROLLER’S
INFORMATION TABLE. FAILURE TO DO SO MAY RESULT IN A
SYSTEM THAT IS SLOW TO RESPOND, OR MAY FAIL TO
RESPOND TO SOME DEVICES.
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Step 8
OPERATION
NOTE: The locator light will illuminate
when the load is in the OFF position to
facilitate access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer's DIM/BRIGHT
bar. The lighting can be controlled from
either the dimmer or the remote location.
Gently lift bottom
of push pad out
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
Press and Hold until lights DIM to lowest level and LED in LED
Brightness Display starts to blink – Lights remain ON for 10
seconds and then turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press upper half of DIM/BRIGHT Bar Lights brighten to desired level.
DIM:
Press lower half of DIM/BRIGHT Bar – Lights dim to desired level.
If you continue to hold the lower half of the DIM/BRIGHT Bar, the
lights will DIM to minimum level and then turn OFF.
NOTE: When lights are OFF you can change the light level that the
lights will turn ON to using the DIM/BRIGHT Bar.
If there is a power outage, when the power is restored the lights will
return to the last setting before the power
interruption.
LED
Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
Step 9
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pulling
the bottom of the push pad until it lifts
completely out of the frame and a click is
heard and all LED’s are OFF (refer to
Figure). This will cut power to the fixture to
replace the bulb. After servicing is
complete, push the push pad back for
normal operation.
Cleaning: Clean with a damp cloth. DO
NOT use chemical cleaners.
ADVANCED PROGRAMMING FEATURES
Mode 1 – Set Minimum Brightness: Set the minimum brightness
level that the lights can dim to prior to turning full OFF.
Mode 2 – Set Dim-Lock: Set the brightness level that the lights
will turn on to regardless of the previous light level at which they
were turned OFF.
Mode 3 – Set Fade Rate: Set the amount of time (in seconds) that
the lights will have to turn ON or OFF. Fade rates can be set to
one of five different settings.
To Program:
NOTE: Have a flashlight handy if this dimmer
controls the only light source in the room.
1. On the dimmer only, engage the air-gap
switch by gently pulling the bottom of the
push pad until it lifts completely out of the
frame and a click is heard and all LED’s are
OFF.
2. Press push pad back into frame and hold
push pad for 7 seconds until the locator light
and the top LED (LED 1) starts blinking.
3. Upon releasing the push pad, the locator
light will continue to blink once per second
indicating the dimmer is in Mode 1, Set
Minimum Brightness mode. To change the
current Minimum Brightness level from 1-50%, use the DIM/BRIGHT
Bar. This setting will automatically be saved.
4. Tap the push pad to change to Mode 2, Set Dim-Lock Level mode.
The locator light will blink twice per second. To change the current
Set Dim-Lock level from 1-100%, use the DIM/BRIGHT Bar. If this
feature is not desired, press and hold the lower half of the DIM/
BRIGHT Bar until no LED is lit. This setting will automatically be
saved.
5. Tap the push pad to change to Mode 3, Set Fade Rate mode. The
locator light will blink 3 times per second. To change the current
Fade Rate, use the DIM/BRIGHT Bar to move the LED to the
desired preset level. This setting will automatically be saved by
tapping the push pad to exit programming mode.
The LED Brightness Display is separated into 7 segments. Each LED
represents a preset level with LED 1 (Preset 1) located at the top and
LED 7 (Preset 7) located at the bottom. Refer to chart for settings and
defaults.
NOTE: The dimmer will exit program mode after 3 minutes of activity.
* default
** LED #1 is located at the top
*** The press and hold feature for the 10 second delayed off is
disabled in this mode.
Preset LED
** Fade On Fade Off
1* 1 Approx. 1.5s from full off Approx. 3s from full on
2
*** 2 No Fade No Fade
3 3 No Fade Approx. 3s from full on
4 4 Approx. 0.5s from full off Approx. 3s from full on
5 5 Approx. 0.5s from full off Approx. 1.5s from full on
6 6 Approx. 1.5s from full off Approx. 5s from full on
7 7 Approx. 1.5s from full off Approx. 10s from full on
Fade Rate Presets
Mode Description Range Default
1 Set Min. Brightness 1-50% 25%
2 Set Dim-Lock Level 0-100%, 0=no lock 0
3 Select Fade Rate 1, 2, 3, 4, 5, 6 or 7 Preset #1
Advanced Features Summary
1
2
3
4
5
6
7
LED
Brightness
Display
DI-000-RZI06-00A-X0
U.S. & Foreign Patents Pending
Copyright
©
2006 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
Programmer/Controller
Cat. No. RZCPG
Center Button