User's Manual

LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benet of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for ve years from
the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such ve year period the product is returned prepaid, with proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation.
This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any
labels or instructions. There are no other or implied warranties of any kind, including merchantability and tness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such
implied warranty, including merchantability and tness for a particular purpose, is limited to ve years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or
loss of use of, any equipment, lost sales or prots or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
OPERATION
NOTE: For complete details on operating the
Primary Programmer/Remote, refer to the
instruction guide for that particular device.
The VRC0P is intended for use by developers
who want to develop products that can
transmit signals to and receive signals from
Vizia RF +
TM
products on a Z-Wave
®
network. A
relatively high level of programming knowledge
is required to develop products that use these
interfaces. The interface uses a simple ACSII
protocol to communicate to the controlling
equipment. If you are an end user who has
purchased this product to work with another
product that was designed for this purpose,
please refer to that product’s owner’s manual for
operating instructions.
If you are a developer who has purchased this
interface to develop a Vizia RF +
TM
compatible
product, you will need the VRC0P Tech Note,
which contains the information needed to allow
proper interface communication. Please visit our
website listed below to download the VRC0P
Tech note.
Plug-In Serial Interface Module is
functioning improperly
- Conrm that the device is being supplied
from a 120V, 60Hz AC source ONLY.
- Conrm that the unit is programmed
properly. Repeat “INSTALLING YOUR
INTERFACE MODULE” section to verify
that it has been included into the Z-Wave
®
network.
Programmer/Remote does not operate
lights
- Check association.
- Ensure that Plug-In Serial Interface Module
was properly updated.
TROUBLESHOOTING
DI-000-VRC0P-02A-X1
© 2009 Leviton Mfg. Co., Inc.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRFplus.com
Protected under U.S. Patent Number 6,388,399
and patents pending and licensed under U.S.
Patents Numbers 5,905,442, and 5,982,103
NOTE: It is very important to accurately
Exclude devices from the network when
moving or removing a device from a Z-Wave
®
network. This ensures that all information has
been removed from your Primary Programmer/
Remote’s information table and is not counted
on to be a part of the mesh network.
A
) If using a Leviton Z-Wave
®
Programmer/
Remote, Cat. No. VRCPG, press the Menu
button and scroll down to System. Press
the center button to select System Menu.
Choose Advanced. Press the center button
to select Advanced Install. Scroll down
to <Exclude Node> and press the center
button.
B) If using VRCPG Programmer/Remote
you will be prompted to prepare device
for exclusion. To do this, you must put
the Plug-In Serial Interface Module into
programming mode.
C) To access Program mode, press and hold
programming button until the LED turns
Amber. Release the button and the LED will
blink Amber. You are now in Programming
mode.
NOTE: If the LED on the Plug-In Serial
Interface Module turns solid Red while
excluding, there has been a communication
error.
D) While standing close to the Plug-In Serial
Interface Module (approximately 1 ft.),
press the center button to <Exclude> device
from the network.
Excluding Plug-In Serial
Interface Module from
Network:
Step 4
Factory Default:
If your module is not responding, or you are
unable to control it after you have tried to Include/
Exclude it multiple times, it may be necessary to
reset the module to its original factory settings. To
accomplish this, proceed as follows:
Press and hold the programming button until
the LED turns Amber and then turns Red.
Release the button and wait until the LED
starts blinking Green. NOTE: This can take up
to a minute. The module is now reset. Once
the module is reset, it will be necessary to Re-
Include it to a network before it can be used.
CAUTION:
SETTING A DEVICE TO A
FACTORY DEFAULT DOES NOT EXCLUDE
THAT DEVICE FROM A NETWORK. THE
EXCLUSION PROCEDURE MUST STILL BE
FOLLOWED TO REMOVE THE DEVICE FROM
THE PRIMARY REMOTE’S INFORMATION
TABLE. FAILURE TO DO SO MAY RESULT IN
SYSTEM THAT IS SLOW TO RESPOND, OR
MAY FAIL TO RESPOND TO SOME DEVICES.
IF YOU HAVE TO RESET THE CONTROLLER
WITHOUT EXCLUDING IT GO TO THE REMOVE
FAILED MENU AND REMOVE THIS DEVICE
FROM YOUR VRCPG REMOTE. REFER TO
VIZIA RF+ APPLICATION GUIDE
(WWW.LEVITON.COM).
Wall Receptacle
RS232 Cable
Plug-In Serial
Interface Module
NOTE: Programmer/Remote must be in close
proximity (approx. 1 foot) to Plug-In Serial
Interface Module when including into network
VRCPG Programmer/
Remote
Including Plug-In
Serial Interface
Module into
Z-Wave
®
Network:
Step 3 cont’d Step 4 cont’d
COMMUNICATION SETTINGS
NOTE: The following general information applies
to the RS232 Interface.
To congure your device to communicate with the
interface, use the following data conventions:
9600 BAUD
8 DATA
1 STOP
NO PARITY
If you wish to send these commands from a
PC, run the Microsoft Windows
®
Hyper Terminal
program or an equivalent program. Then select
Local Echo, Line Feed and Carriage Return
inbound and outbound. This allows you to see the
characters that you are typing as well as keep the
responses from overwriting typed characters.
www.ViziaRFplus.com
RJ11 DB9 PIN-OUTS
4 (BLACK)
3 (RED)
2 (GREEN)
1 (YELLOW)
2 (TX)
(Not used)
3 (RX)
5 (SGND)
RJ11 RJ11 HAI PATCH CORD PIN-OUTS
4 (BLACK)
2 (GREEN)
3 (RED)
1 (YELLOW)
1 (TX)
2 (RX)
(Not used)
4 (SGND)
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC
Rules. Operation is subject to following two
conditions: (1) this device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation of the device.
This equipment has been tested and found
to comply with the limits for a Class B Digital
Device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide
reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses, and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. However, there is
no guarantee that interference will not occur
in a particular installation. If this equipment
does cause harmful interference to radio or
television reception, which can be determined
by turning the equipment OFF and ON,
the user is encouraged to try to correct the
interference by one or more of the following
measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the
equipment and the receiver.
Connect the equipment into an outlet on
a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/
tv technician for help.
FCC CAUTION
Any changes or modications not expressly
approved by Leviton Manufacturing Co., Inc.,
could void the user's authority to operate the
equipment.