User's Manual

Excluding Receptacle from Z-Wave
®
Network:Including Receptacle into Z-Wave
®
Network:
DI-000-VRR15-02A
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,
at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor
for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Programmer/Controller
Cat. No. VRCPG
NOTE: Programmer/Controller must be in close
proximity to receptacle when including in the network.
For additional information, contact Leviton’s
Techline at 1-800-824-3005 or visit Leviton’s
website at www.ViziaRFplus.com
Protected under U.S. Patent Number 6,388,399 and patents pending
and licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
CONTROLLED
Programming
button
Locator
Light
NOTE: The locator light will illuminate when receptacle is connected.
If there is a power outage, when the power is restored, the lights will return
to the last setting before the power interruption.
Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.
OPERATION
TROUBLESHOOTING
• Receptaclehasnopower
- Receptacle has a bad connection.
- Wires not secured rmly under terminal screws of receptacle.
• LocatorLEDdoesnotturnON
- Circuit breaker or fuse has tripped.
- Neutral connection is not wired.
- Press progarmming button.
Step 9
NOTE: It is very important to accurately Exclude devices from the network
when moving or removing a device from a Z-Wave
®
network. This ensures
that all information has been removed from your Primary.
A) If using a Leviton Z-Wave
®
Programmer/Controller, Cat. No. VRCPG,
press the Menu button and scroll down to System. Press the center
button to select. Choose Advanced. Press the center button to select
Advanced Install. Scroll down to exclude.
B) While standing close to the receptacle (approximately 1 foot), press the
center button to <Exclude> device from the network.
C) While the Programmer/Controller is in the Exclusion mode and the
locator LED is ON press the button. The Programmer/Controller will
verify Exclusion and the locator LED will turn OFF.
If the receptacle is ashing Amber while in the Exclusion mode, the
Programmer/Controller is still trying to communicate with the receptacle.
Wait until the device stops ashing, then press the receptacle program
button.
Factory Default:
If your receptacle is not responding, or you are unable to control it after you
have tried to Include/Exclude it multiple times, it may be necessary to reset
the receptacle to its original factory settings. To accomplish this, proceed as
follows:
On the receptacle, press and hold the program button until the locator
LED turns Amber and then ashes Red. The receptacle is now reset.
Once the receptacle is reset, it will be necessary to Re-Include it to a
network before it can be used.
CAUTION: SETTING A DEVICE TO A FACTORY DEFAULT DOES
NOT EXCLUDE THAT DEVICE FROM A NETWORK. THE EXCLUSION
PROCEDURE MUST STILL BE FOLLOWED TO REMOVE THE DEVICE
FROM THE PRIMARY CONTROLLER’S INFORMATION TABLE. FAILURE
TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR
MAY FAIL TO RESPOND TO SOME DEVICES.
Step 8
NOTES:
Receptacle will be included as a switch
If using a non-Leviton Programmer/Controller, refer to the
Programmer/Controller instruction sheet for Including a device.
If using VRCPG install checklist go directly to step B.
A) If using a Leviton Z-Wave
®
Programmer/Controller, Cat. No. VRCPG,
press the Menu button and scroll down to System. Press the center
button to select System Menu. Choose Advanced. Press the center
button to select Advance Install.
B) While standing close to the receptacle (approximately 1 foot), press
the center button to <Include> device in the network.
NOTE: Only one device may be included at a time. DO NOT put
multiple devices into the Inclusion mode at any time.
C) While the Programmer/Controller is in the Inclusion mode and
the Locator LED is ON on the receptacle, press the button on the
receptacle. The Programmer/Controller will verify inclusion.
If the receptacle is ashing Amber while in the Inclusion mode,
the Programmer/Controller is still trying to communicate with the
receptacle. Wait until the device stops ashing, then press the
receptacle program button.
NOTE: If the Locator LED on the receptacle turns solid Red
while including, there has been a communication error. Refer to
Troubleshooting section.
D) The Primary Programmer/Controller will assign a node ID number
(Name) for this device.
NOTE: This ID number (Name) will be stored in the controller to be
used for future reference.
NOTE: You may name or edit your device at this time.
E) The receptacle is now installed in the network.
NOTE: If the receptacle has been
successfully Included in the network and
the user tries to Include it again without rst
excluding it from the network, the receptacle
will retain the rst node ID it had received
and ignore the second.
1 ON
2 ON
3 ON
4 ON
OFF
OFF
OFF
OFF
Programmer/Controller
Cat. No. VRCPG
Menu
Button
Center
Button
Gently press
Programming button
© 2009 Leviton Mfg. Co., Inc.
FCC COMPLIANCE STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject
to following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment OFF and ON, the user is encouraged to try to
correct the interference by one or more of the following measures:
Reorient or relocate the receiving Antenna.
Increase the separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/tv technician for help.
FCC CAUTION
Any changes or modications not expressly approved by Leviton
Manufacturing Co., Inc., could void the user's authority to operate the
equipment.