Preparing and connecting wires:
This dimmer can be wired using side wire terminal
screws or through backwire openings. Choose
appropriate wire stripping specifications accordingly.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to terminal screw marked “BK”.
• Load wall box wire to terminal screw marked “RD”.
• Dimmer terminal screw marked “YL/RD” should have Red
insulation label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
“YL/RD”, use electrical tape to cover.
• ProceedtoStep5.
Hot (Black)
Neutral (White)
Load
Dimmer
BK
Black
White
RD
Green
Ground
Line
120VAC, 60Hz
YL/RD
Use Terminal for 3-Way or
More Applications Only.
For Single Pole Applications,
DoNotRemoveThisLabel.
• Makesurethattheendsofthewiresfromthewallboxare
straight (cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
• ForSinglePoleApplication,gotoStep4a.
• For 3-Way Coordinating Remote (no LEDs) Application, go to
Step4b.
• For 3-Way Matching Remote (with LEDs) Application, go to
Step4c.
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,uorescentlighting,amotor-oratransformer-
operated appliance.
• Usewithincandescentor120Vhalogenxturesonly.
• Vizia+™dimmersarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™remotesformulti-locationdimming.
• Useonlyone(1)Vizia+™dimmerinamulti-locationcircuitwithupto9coordinatingremotes(withoutLEDs)orupto4matchingremotes(withLEDs).Theremote(s)
will turn the light on at the brightness level selected at the dimmer.
WARNINGS AND CAUTIONS:
• Dimmermaynotoperatewithdiodedlamps(SylvaniaDesigner16™orPhilipsPAR-16™).
• Totalminimumloadmustexceed40W.
• Dimmermayfeelwarmtothetouchduringnormaloperation.
• Recommendedminimumwallboxdepthis2-1/2”.
• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft.
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
Step 4a cont’d
IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a
different color (Black) or labeled Common. Tag that wire with
electrical tape and identify as the common (Line or Load) in both the
dimmer wall box and remote wall box.
Strip Gage
(measure bare wire
here or use gage on
back of the dimmer)
5/8”
(1.6cm)
Cut
(if necessary)
Back Wire
(either hole may be used)
Backwireopeningsuse#14-12
AWG solid copper wire only.
Side Wire Connection
Sidewireterminalsaccept#14
AWG solid copper wire only.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE:WhenusingthecoordinatingremotewithoutLEDs,thedimmer
can be installed on either the Line or Load side of the 3-way circuit.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when removing
old switch to terminal screw marked “BK”.
• First Traveler wall box wire to terminal screw marked “RD” (note
wire color). This traveler from the dimmer must go to the terminal
screw on the remote marked “RD”.
• Remove Red insulating label from terminal screw marked “YL/RD”.
• Second Traveler wall box wire to terminal screw marked “YL/RD”
(note wire color). This traveler from the dimmer must go to the
terminal screw on the remote marked “YL/RD”.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE: Maximum wire length from dimmer to last remote is 300ft.
• Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch to
terminal screw marked “BK”.
• First Traveler wall box wire (note color as above) to terminal
screw marked “RD”. This traveler from the remote must go to the
terminal screw on the dimmer marked “RD”.
• Second Traveler wall box wire (note color as above) to terminal
screw marked “YL/RD”. This traveler from the remote must go to
the terminal screw on the dimmer marked “YL/RD”.
• Remote terminal screw marked “WH” should have White insulation
label affixed.
NOTE: If insulating label is not affixed to terminal screw marked
“WH”, use electrical tape to cover.
• ProceedtoStep5.
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD
YL/RD
RD
WH
RD
BK
BK
Black
Do not use for
incandescent
applications.
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Push in side
at tab to release
Line up tabs and
press in sides one at
a time to attach
Tools needed to install your Dimmer
Installing Dimmer by itself or with other devices
Slotted/PhillipsScrewdriver ElectricalTape Pliers
Pencil Cutters Ruler
Changing the color of your device:
Your device may include color options. To change color of the face
proceed as follows:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
MULTI-DEVICE APPLICATION:
In multi-dimmer installations, the reduction of the dimmer’s capacity
isrequired.Refertothechartformaximumloadperdimmer.
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE APPLICATION
Cat.No.
VPI
Ø
6
Single
600W
Two Devices
500W
More than 2
Devices
400W
√
INSTALLING YOUR DIMMER
NOTE: UsecheckboxeswhenStepsarecompleted.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
2
4
1
5
3
3-Way
1. Line or Load (See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE:Formatchingremotew/LEDs
installation, the First Traveler becomes
Line Hot.
2
4
3
1
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Step 2
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble any
ofthesecongurations,consultaqualiedelectrician.
Step 3
T e rminal
Screw marked
Red (RD)
2
BK
RD
YL/RD
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Ye llow/Red
(YL/RD)
T e rminal Label:
Use Terminal for 3-Way or More Applications Only.
For Single Pole Applications, Do Not Remove This
Label.
4
1
3
Single Pole Wiring Application:
Step 4a
2
T e rmi nal
Screw marke d
Red (R D)
Coordinating Remote
2
4
Dimmer
BK
RD
YL/RD
BK
RD
YL/RD
1
3
5
3
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
1
4
(Coordinating Dimming Remote Depicted)
3-Way Wiring with Coordinating
Dimming or Switching Remote (no LEDs)
Application:
Step 4b