Instructions / Assembly

Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON to preset level.
Press and Hold – Lights turn ON to full bright.
Turn OFF from ON position:
Tap – Lights turn OFF.
DIM/BRIGHT Bar
BRIGHTEN:
Press right half of DIM/BRIGHT Bar – Lights brighten to desired level.
DIM:
Press left half of DIM/BRIGHT Bar – Lights dim to desired level.
If you continue to hold the left half of the DIM/BRIGHT Bar, the lights will
DIM to minimum level and then turn OFF.
Air-Gap Switch: On the dimmer only,
engage the air-gap switch by gently pressing
the top of the push pad until the bottom lifts
completely out of the frame and a click is
heard (refer to Figure).LEDswillturnOFF.
This will stop power to the fixture to replace
the bulb. After servicing is complete, press
the push pad back into place for normal
operation.
Cleaning: Clean with a damp cloth.
DO NOT use chemical cleaners.
LIMITED5YEARWARRANTYANDEXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of
purchase date, and a description of the problem to LevitonManufacturingCo.,Inc.,Att:QualityAssuranceDepartment,59-25LittleNeckParkway,LittleNeck,NewYork11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused,
or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose,butifanyimpliedwarrantyisrequiredbytheapplicablejurisdiction,thedurationofanysuchimpliedwarranty,includingmerchantabilityandtnessforaparticularpurpose,is
limited to five years. Levitonisnotliableforincidental,indirect,special,orconsequentialdamages,includingwithoutlimitation,damageto,orlossofuseof,anyequipment,lostsalesorprotsordelayorfailuretoperformthiswarrantyobligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Dimmer
Remote (with LEDs)
YL/RD
YL/RD
RD
WH
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The matching remote must be installed in a wall box
with a Line Hot connection and a Neutral connection. A Neutral
wire to the matching remote needs to be added as shown.
If you are unsure about any part of these instructions, consult a
qualiedelectrician.
NOTE: Maximum wire length from dimmer to all installed remotes
cannot exceed 300 ft.
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
• Line Hot (common) wall box wire identified (tagged) when
removing old switch and First Traveler to remote terminal screw
marked “BK”.
• Second Traveler wall box wire from dimmer to remote terminal
screw marked “YL/RD” (note wire color). This traveler from the
remote must go to the terminal screw on the dimmer marked
“YL/RD”.
• Line Neutral wall box to remote terminal screw marked “WH”.
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
• Load wall box wire identified (tagged) when removing old switch
to dimmer terminal screw marked “RD”.
• First Traveler Line Hot to dimmer terminal screw marked “BK”.
• Remove Red insulating label from terminal screw marked
“YL/ RD”.
• Second Traveler wall box wire (note color as above) to dimmer
terminal screw marked “YL/RD”. This traveler from the dimmer
must go to the terminal screw on the remote marked “YL/RD”.
• ProceedtoStep5.
2
Additional
Neutral Wire
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
BK
RD
YL/RD
BK
RD
YL/RD
4
3
1
5
T e rminal
Screw marked
Red (RD)
Matching Dimmer Remote
Dimmer
4
3
1
2
5
DI-000-VPI06-02A
Position all wires to provide room in
outlet wall box for device.
• Ensurethattheword“TOP”isfacing
up on device strap.
• Partially screw in mounting screws
in wall box mounting holes.
• Restorepoweratcircuitbreakerorfuse.
• Press pad until locator light is OFF. Lights
should turn ON. If lights do not turn ON,
press the upper half of DIM/BRIGHT bar
until the lights brighten.
If lights still do not turn ON, refer to the
TROUBLESHOOTINGsection.
NOTE: The turn on light level can be changed when lights are
off using the DIM/BRIGHT Bar. In the event of power outage or
interruption, the lights will reset to the last level when power is
restored.
LED Brightness
Display
DIM/BRIGHT
Bar
Push
Pad
Locator
Light
Testing your Dimmer prior to mounting in
wall box:
Step5
A-2) TheLocatorLEDwillblink2timespersecondtoindicatethe
device is in Program Mode A-2, Minimum Brightness Level.
ThedefaultMinimumBrightnessLevelisLED2.Tochangethe
Minimum Brightness Level from 1-50%, use the DIM/BRIGHT
Bar.Thelightoutputwillreecttheminimumbrightnesslevel
selected. By tapping the Push Pad this setting will automatically
be saved and the device will advance to the next programming
mode, A-3.
A-3) TheLocatorLEDwillblink3timespersecondtoindicate
Program Mode A-3, Preset ON Level. To change the current
Preset ON Level from 1-100%, use the DIM/BRIGHT Bar. If
this feature is not desired, press and hold the left half of the
DIM/BRIGHT Bar (
v
)
untilnoLEDislit(defaultsetting).By
tapping the Push Pad this setting will automatically be saved and
the device will advance to the next programming mode, A-4.
A-4) TheLocatorLEDwillblink4timespersecondtoindicate
Program Mode A-4, Almost OFF Level. To change the current
Almost OFF Level,usetheDIM/BRIGHTBartoadjustthe
preset light level. If this feature is not desired, press and hold
the right half of the DIM/BRIGHT Bar (
^
)untilnoLEDislit
(default setting). Almost OFF can be overridden by pressing
and holding the left half of the DIM/BRIGHT Bar (
v
). By tapping
the Push Pad this setting will automatically be saved and the
device will exit Programming Mode A.
NOTE: When Almost OFF LevelissettheLEDLocatorwillbe
illuminated when the dimmer is in the Almost OFF state, even though
the light remains on.
Program Mode B
To enter Program Mode B:
Press and hold the Push Pad and then the left half of the
DIM/BRIGHT Bar (
v
)for5secondsuntiltheLocatorLEDand
rightmostLED(LED7)begintoblink.
B-1) UponreleasingthePushPadandtheleft half of the
DIM/BRIGHT Bar (
v
),theLocatorLEDwillcontinuetoblink
once per second indicating he dimmer is in Program Mode
B-1, ON Fade Rate. To change the ON Fade Rate, use the
DIM/BRIGHTBartomovetheLEDtothedesiredpresetlevel
according to Chart B. By tapping the Push Pad this setting will
automatically be saved and the device will advance to the next
programming mode, B-2.
B-2) TheLocatorLEDwillblink2timespersecondtoindicate
Program Mode B-2, OFF Fade Rate. To change the OFF Fade
Rate,usetheDIM/BRIGHTBartomovetheLEDtothedesired
preset level according to Chart B. By tapping the Push Pad this
setting will automatically be saved and the device will advance
to the next programming mode, B-3.
Step 4c
3-Way Wiring with Matching Remote
(w/LEDs) Application:
Restore Power: Restore power at circuit breaker
or fuse.
Installationiscomplete.
Step 7
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR
FUSE.
Step 6
Installation may now be
completed by tightening
mounting screws into wall box.
Attach wallplate.
ThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassB
Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation.Thisequipmentgenerates,uses,andcanradiateradiofrequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that
interferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescause
harmful interference to radio or television reception, which can be determined by
turningtheequipmentOFFandON,theuserisencouragedtotrytocorrectthe
interference by one or more of the following measures:
• ReorientorrelocatethereceivingAntenna.
• Increasetheseparationbetweentheequipmentandthereceiver.
• Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthe
receiver is connected.
• Consultthedealeroranexperiencedradio/tvtechnicianforhelp.
FCC COMPLIANCE STATEMENT
For additional information, contact Leviton’s Techline at
1-800-824-3005orvisitLeviton’swebsiteatwww.leviton.com
CoveredbyoneormoreUS&Foreign
Patents and patents pending
Copyright
© 2008 Leviton Manufacturing Co., Inc.
All Rights Including Trade Dress Rights Reserved
• Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly under terminal screws of dimmer
and/or remote.
• Light does not turn ON and Locator LED does not turn ON
- Circuit breaker or fuse has tripped.
- Lamp is burned out.
- Lamp Neutral connection is not wired.
• Intermittent dimmer operation
-Minimumloadisunder40W.
• Remote does not operate lights
-Ensurethattotalwirelengthdoesnotexceed300ft.
TROUBLESHOOTING
OPERATION
NOTE: The locator light will illuminate
when the load is in the OFF position to
facilitate access in the dark.
NOTE: If using the dimmer in a 3-way
application, the lights will turn ON at
brightness set on dimmer’s DIM/BRIGHT
bar. The lighting can be controlled from
either the dimmer or the remote location.
ADVANCED PROGRAMMING FEATURES
Definition of A Modes
A-1) EnergySave: Sets the maximum brightness level for energy
savings.
A-2) Minimum Brightness Level: Sets the minimum dimming level.
A-3) Preset ON Level: Sets the turn on brightness level regardless
of the previous set light level (formerly Dim Lock).
A-4) Almost OFF Level: Sets the brightness level the device will dim
to when the push pad is pressed to turn off. In this mode the
lights will always remain on.
Definition of B Modes
B-1) ON Fade Rate: Sets the amount of time in seconds it takes the
lights to turn ON to maximum brightness.
B-2) OFF Fade Rate: Sets the amount of time in seconds it takes
the lights to turn OFF from maximum brightness.
B-3) LEDOptions:SetsthetimeperiodinsecondstheLocatorLED
and Brightness display will stay on before extinguishing.
Definition of C Modes
C) Restore Defaults: Restores the factory default settings.
Definition of LEDs
LeftmostLED=LED1
RightmostLED=LED7
NOTES:
• Thedevicewillexitprogramming
mode after 3 minutes of inactivity.
• PressingthePushPadatanytime
during programming will advance
the device to the next programming
mode.
LED Brightness
Display
1 2 3 4 5 6 7
Program Mode A
To enter Program Mode A:
Press and hold the Push Pad and then the right half of the DIM/
BRIGHT Bar
(
^
)
for5secondsuntiltheLocatorLEDandleftmost
LED(LED1)begintoblink.
A-1) UponreleasingthePushPadandtheright half of the
DIM/BRIGHT Bar
(
^
)
,theLocatorLEDwillcontinuetoblink
oncepersecondandtherightmostLEDwillilluminateto
display the device is in Program Mode A-1, Energy Save. The
default energy save mode is 100% i.e. full bright. To change
the Energy Save level, use the DIM/BRIGHT Bar to move
thecorrespondingLEDtothedesireddiscretepresetlevel
according to Chart A. By tapping the Push Pad this setting will
automatically be saved and the device will advance to the next
programming mode, A-2.
NOTE: Dress wires with a bend
as shown in diagram in order to
relieve stress when mounting
device.
LED
LED 1
LED 2 (Default)
LED 3
LED 4
LED 5
LED 6
LED 7
FADE ON
0 seconds (instant)
0.5 seconds
1.5 seconds
3.0 seconds
6.0 seconds
10 seconds
25 seconds
0 seconds (instant)
0.5 seconds
1.5 seconds
3.0 seconds
6.0 seconds
10 seconds
25 seconds
FADE OFF
B-3)
TheLocatorLEDwillblink3timespersecondtoindicate
Program Mode B-3, LED Options. To change the LED
Options settings, use the DIM/BRIGHT Bar to move the
LEDtothedesiredpresetsettingaccordingtotheChart
B-3. By tapping the Push Pad this setting will automatically
be saved and the device will exit Programming
Mode B.
LED
LED 1
LED 2
LED 3
LED 4
LED 5
LED 6
LED 7
LOCATOR LED TIMEOUT
Active
Active
Turns off 5 sec. after use
Turns off 5 sec. after use
N/A
N/A
N/A
LED BRIGHTNESS DISPLAY OPTIONS
Active
Turns off 5 sec. after use
Active
Turns off 5 sec. after use
N/A
N/A
N/A
Chart B
Gently press top
of push pad
Program Mode C
To enter Program Mode C:
Engagetheair-gapswitchbygently
pressing the top of the Push Pad until the
bottom lifts completely out of the frame and
aclickisheard.AllLEDswillextinguish.
C) Press Push Pad back into the frame
andholdfor7secondsuntiltheLED
Brightness Display starts bidirectional
strobing to indicate Program Mode
C, Restore Default. To Restore
Default settings, release the Push
Pad. This will exit programming
mode C.
Gently press top
of push pad
Chart A
Chart B-3
When indicator
light is at LED #
7
6
5
4
3
2
1
Light output is at
100%
97%
95%
90%
85%
80%
75%
Energy consumption
savings amounts to
0%
5%
8%
11%
14%
17%
20%