Instructions / Assembly

3-Way or More Applications (Multi-location)
Remote Devices
Cat. No. VP00R-10, Coordinating Dimmer Remote
Cat. No. VP00R-1L, Matching Dimmer Remote
Cat. No. VP0
S
R-10, Coordinating Switch Remote
Cat. No. VP0
S
R-1L, Matching Switch Remote
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• Tobeinstalledand/orusedinaccordancewithappropriateelectricalcodesandregulations.
• Ifyouareunsureaboutanypartoftheseinstructions,consultaqualiedelectrician.
• Toavoidoverheatingandpossibledamagetothisdeviceandotherequipment,donotinstalltocontrolareceptacle,uorescentlighting,amotor-ora
transformer-operatedappliance.
• ForHi-lume
®
or Eco-10
®
(EcoSeries)electronicballastapplications,useinstructionsheetthatcomeswiththedimmerformulti-locationapplications.
• Vizia+™remotesarenotcompatiblewithstandard3-wayor4-wayswitches.TheymustbeusedwithcompatibleVizia+™orViziarf+™devicesformulti-location
switching.
WARNINGS AND CAUTIONS:
• Useonlyone(1)Vizia+™dimmerinamulti-locationcircuitwithupto9coordinatingremoteswithoutLEDsorupto4matchingremoteswithLEDs.Theremote(s)
willturnthelightonatthebrightnesslevelselectedatthedimmer.
• Recommendedminimumwallboxdepthis2-1/2".
• Maximumwirelengthfromdimmertoallinstalledremotescannotexceed300ft(90m).
• Disconnectpoweratcircuitbreakerorfusewhenservicing,installingorremovingxture.
• Usethisdeviceonlywithcopperorcoppercladwire.WithaluminumwireuseonlydevicesmarkedCO/ALRorCU/AL.
Tools needed to install your Remote:
Slotted/PhillipsScrewdriver ElectricalTape
Pliers Pencil
Cutters Ruler
INSTALLING YOUR REMOTE
NOTE:UsecheckboxeswhenStepsarecompleted.
Step 1
WARNING: TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER atcircuitbreakerorfuseandtest
thatpowerisoffbeforewiring!
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
3
5
1
2
6
4
2
4
1
5
3
4-Way
1. FirstTraveler–notecolor
2. SecondTraveler–tagged
3. Neutral
4. Ground
5. ThirdTraveler–notecolor
6. FourthTraveler–tagged
NOTE:Formatchingremote
w/LEDsinstallation,theFirst
TravelerbecomesLineHot.
3-Way
1. Line or Load (See important
instruction below)
2. Neutral
3. Ground
4. FirstTraveler–notecolor
5. SecondTraveler–notecolor
NOTE:Formatchingremote
w/LEDsinstallation,theFirst
TravelerbecomesLineHot.
Identifying your wiring application (most
common):
NOTE:Ifthewiringinthewallboxdoesnotresemble
anyofthesecongurations,consultaqualied
electrician.
Step 2
IMPORTANT:
For 3-Way applications,notethatoneofthescrewterminalsfrom
theoldswitchbeingremovedwillusuallybeadifferentcolor(Black)
orlabeledCommon.Tagthatwirewithelectricaltapeandidentify
asthecommon(LineorLoad)inboththedimmerwallboxand
remotewallbox.
For 4-Way applications,notethattheoldswitchbeingremoved
willhave4screwsplusagroundscrew.Tagthetwosamecolor
insulated wires with electrical tape.
3-Way Wiring with Matching Remote (w/LEDs)
Application:
NOTE: IncandescentandMagneticLowVoltage
installations only.
NOTE: Screw terminal dimmer depicted.
Step 4a
Coordinating Remote
Dimmer
BK
RD
YL/RD
T e rminal
Screw marked
Black (BK)
T e r mi na l
Scr ew mar ke d
Red ( RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
2
4
3
5
1
BK
RD
YL/RD
2
4
3
5
1
Hot (Black)
Neutral (White)
Load
Dimmer
Coordinating Remote (no LEDs)
YL/RD
YL/RD
RD
WH
RD
BK
BK
Black
not used
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no LEDs)
Application:
NOTE: IncandescentandMagneticLowVoltage
installations only. NOTE: Screw terminal dimmer
depicted.
Step 4b
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallboxwith
a Line Hot connection and a Neutral connection. A Neutral wire to the
matchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft.
Wiring Matching Remote (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoremoteterminalscrewmarked“BK”
ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminal
screwmarked“YL/RD”(note wire color).Thistravelerfromthe
remotemustgototheterminalscrewonthedimmermarked
“YL/RD”ortheYellow/Reddimmerlead.
• LineNeutralwallboxtoremoteterminalscrewmarked“WH”.
Wiring Dimmer (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green dimmer lead.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
dimmerterminalscrewmarked“RD”ortheReddimmerlead.
• FirstTravelerLineHottodimmerterminalscrewmarked“BK”orthe
Blackdimmerlead.
• RemoveRedinsulatinglabelfromterminalscrewmarked“YL/RD”
orYellow/Reddimmerlead.
• SecondTravelerwallboxwire(notecolorasabove)todimmer
terminalscrewmarked“YL/RD”ortheYellow/Reddimmerlead.
Thistravelerfromthedimmermustgototheterminalscrewonthe
remotemarked“YL/RD”.
• ProceedtoStep6.
Step 4d cont’d
Cut
(if necessary)
Preparing and connecting wires:
Thisremotecanbewiredusingsidewireterminal
screwsorthroughbackwireopenings.Choose
appropriatewirestrippingspecicationsaccordingly.
Step 3
Side Wire Connection
Side wire terminals accept
#14AWGsolidcopperwire
only.
Back Wire
(either hole may be used)
Backwireopeningsuse
#14-12AWGsolidcopperwireonly.
5/8"
(1.6 cm)
Strip Gage (measure bare wire here or
use gage on back of the dimmer)
• Makesurethattheendsofthewiresfromthewallboxarestraight
(cut if necessary).
• Removeinsulationfromeachwireinthewallboxasshown.
PK-93461-10-00-2A
Changing the color of your Device:
Yourdevicemayincludecoloroptions.Tochangecoloroftheface
proceedasfollows:
Push in side at tab
to release
Line up tabs and
press in sides one at
a time to attach
BK
RD
YL/RD
4
3
2
1
5
Dimmer
Matching Remote
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote (w/LEDs)
YL/RD
YL/RD
RD
WH
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Step 2 cont’d
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: When using the coordinating remote without LEDs, the dimmer
canbeinstalledoneithertheLineorLoadsideofthe3-waycircuit.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green dimmer lead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchtodimmerterminalscrewmarked"BK"orBlackdimmer
lead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed
dimmer lead (note wire color).Thistravelerfromthedimmermust
gototheterminalscrewontheremotemarked"RD".
• RemoveRedinsulatinglabelfromterminalscrewmarked
"YL/RD"orYellow/Reddimmerlead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"or
Yellow/Reddimmerlead(note wire color).Thistravelerfromthe
dimmermustgototheterminalscrewontheremotemarked"YL/RD".
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:Maximumwirelengthfromdimmertolastremoteis
300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitchto
terminalscrewmarked"BK".
• FirstTravelerwallboxwire(note color as above) to terminal screw
marked"RD".Thistravelerfromtheremotemustgototheterminal
screwonthedimmermarked"RD"orReddimmerlead.
• SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"YL/RD".Thistravelerfromtheremotemustgoto
theterminalscrewonthedimmermarked"YL/RD"orYellow/Red
dimmer lead.
• Remoteterminalscrewmarked"WH"shouldhaveWhiteinsulation
labelafxed.
NOTE:Ifinsulatinglabelisnotafxedtoterminalscrewmarked
"WH",useelectricaltapetocover.
• Proceed to Step 6.
3-Way Wiring with Matching Remote
(w/LEDs) for Controls with Neutral Connection
Application:
NOTE:ElectronicLowVoltage,Mark10™,QuietFan
Speed and Electronic Switch installations only.
NOTE: Dimmer is depicted.
Step 4c
4
3
5
Control
Matching Remote
Black
Green
White
Red
Yellow/Red
1
2
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallboxwith
a Line Hot connection and a Neutral connection. A Neutral wire to the
matchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromcontroltoallinstalledremotes
cannotexceed300ft(90m).
WIRING MATCHING REMOTE (wall box with Line Hot
connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchandFirstTravelertoterminalscrewmarked"BK"orBlack
dimmer lead.
• SecondTravelerwallboxwirefromcontroltoremoteterminalscrew
marked"YL/RD"(note wire color).Thistravelerfromtheremote
mustgototerminalscrewmarked"YL/RD"orYellow/Redcontrol
lead.
• LineNeutralwallboxtoremoteterminalscrewmarked"WH".
WIRING DIMMER (wall box with Load connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green control lead.
• Loadwallboxwireidentied
(tagged)whenremovingoldswitch
toterminalscrewmarked"RD"or
Red control lead.
• FirstTravelerLineHottoterminal
screwmarked"BK"orBlack
control lead.
• RemoveRedinsulatinglabelfrom
terminalscrewmarked"YL/RD"or
Yellow/Redcontrollead.
• SecondTravelerwallboxwire
(note color as above) to terminal
screwmarked"YL/RD"orYellow/Redcontrollead.Thistraveler
fromthecontrolmustgototheterminalscrewontheremote
marked"YL/RD".
• Lineneutralwallboxwiretoterminalscrewmarked"WH"or
White control lead.
• Proceed to Step 6.
BK
RD
YL/RD
Control
Coordinating Remote
3
1
3
4
5
Black
White
Green
Red
Yellow/Red
2
1
4
T e rminal
Screw marked
White (WH)
Terminal
Screw marked
Y e llow/Red
(YL/RD)
2
5
Hot (Black)
Neutral (White)
ControlrCoo dinating Remote (no LEDs)
YL/RD
YL/RD
RD
White
Red
Black
Black
BKWH
White
Load
Line
120V A C, 60Hz
not used
not used
Green
Ground
Green
Ground
3-Way Wiring with Coordinating Remote (no
LEDs) for Controls with Neutral Connection
Application:
NOTE:ElectronicLowVoltage,Mark10™,Quiet
FanSpeedandElectronicSwitchinstallationsonly.
NOTE: Dimmer is depicted.
Step 4d
WIRING CONTROL:
Connect wires per WIRING DIAGRAM as follows:
NOTE:ThecontrolmustbeinstalledinawallboxthathasaLineHot
Connection.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrewor
Green control lead.
• LineHot(common)wallboxwireidentied(tagged)whenremoving
oldswitchtoterminalscrewmarked"BK"orBlackcontrollead.
• FirstTravelerwallboxwiretoterminalscrewmarked"RD"orRed
control lead (note wire color).
• RemoveRedinsulatinglabelfromterminalscrewmarked"YL/RD"
orYellow/Redcontrollead.
• SecondTravelerwallboxwiretoterminalscrewmarked"YL/RD"
orYellow/Redcontrollead(note wire color).Thistravelerfrom
thecontrolmustgototheterminalscrewontheremotemarked
"YL/RD".
• LineNeutralwallboxwiretoterminalscrewmarked"WH"orWhite
control lead.
WIRING COORDINATING REMOTE:
Connect wires per WIRING DIAGRAM as follows:
NOTE:"BK"and"RD"terminalsoncoordinatingremoteare
unused.Tightenbothscrews.
NOTE:Maximumwirelengthfromcontroltolastremoteis
300ft(90m).
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• Loadwallboxwireidentied(tagged)whenremovingoldswitch
toFirstTraveler(note color as above).
• SecondTravelerwallboxwire(note color as above) to terminal
screwmarked"YL/RD".Thistravelerfromtheremotemustgoto
theterminalscrewmarked"YL/RD"orYellow/Redcontrollead.
• RemoveWhiteinsulatinglabelfromterminalscrewmarked
"WH".
• LineNeutralwallboxwiretoterminalscrewmarked"WH".
• Proceed to Step 6.
4-Way Wiring with Matching Remote (w/LEDs)
Application:
NOTE:IncandescentandMagneticLowVoltage
installations only.
NOTE: Screw terminal dimmer depicted.
Step 5a
BK
RD
YL/RD
BK
RD
YL/RD
4
3
2
1
5
Matching Remote
(3-Way Wall box from Step 2)
Matching Remote
(4-Way Wall box from Step 2)
Dimmer
(3-Way Wall box from Step 2)
4
3
5
Additional
Neutral Wire
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
White (WH)
6
2
1
T e rminal
Screw marked
White (WH)
Additional
Neutral Wire
BK
RD
YL/RD
4
3
1
2
5
T e rminal
Screw marked
Black (BK)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
T e rminal
Screw marked
Y e llow/Red
(YL/RD)
Hot (Black)
Neutral (White)
Load
Dimmer
Matching Remote
(w/LEDs)
Matching Remote
(w/LEDs)
YL/RD
YL/RD
YL/RD
RD
WHWH
BK
BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Green
Ground
NOTE:ThedimmermustbeinstalledinawallboxthathasaLoad
connection.Thematchingremotemustbeinstalledinawallbox
with a Line Hot connection and a Neutral connection. A Neutral wire
tothematchingremoteneedstobeaddedasshown.
Ifyouareunsureaboutanypartoftheseinstructions,consulta
qualiedelectrician.
NOTE:Maximumwirelengthfromdimmertoallinstalledremotes
cannotexceed300ft(90m).
WIRING MATCHING REMOTE (4-Way wall box with Line
Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• FirstTravelerandThirdTravelerwallboxwirefromdimmerin
the3-wayboxtoremoteterminalscrewmarked"BK"inthe
4-waybox,andtotheterminalscrewmarked"BK"ofthe
remainingremoteinthe3-waybox.
• SecondTraveler(tagged)andFourthTraveler(tagged)wallbox
wirefromdimmerinthe3-wayboxtoremoteterminalscrew
marked"YL/RD"inthe4-waybox,andtotheterminalscrew
marked"YL/RD"oftheremainingremoteinthe3-waybox(note
wire colors).Thistravelerfromtheremotesmustgotothe
terminalscrewonthedimmermarked"YL/RD"ortheYellow/Red
dimmer lead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked
"WH".
WIRING MATCHING REMOTE (3-Way wall box with Line
Hot connection):
Connect wires per WIRING DIAGRAM as follows:
• GreenorbarecopperwireinwallboxtoGreenterminalscrew.
• LineHot(common)wallboxwireidentied(tagged)when
removingoldswitchandFirstTravelerdimmerterminalscrew
marked"BK"ortheBlackdimmerlead.
• SecondTravelerwallboxwirefromdimmertoremoteterminal
screwmarked"YL/RD"(note wire color as above).Thistraveler
fromtheremotemustgototheterminalscrewonthedimmer
marked"YL/RD"ortheYellow/Reddimmerlead.
• LineNeutralwallboxwiretoremoteterminalscrewmarked
"WH".

Summary of content (2 pages)