Installation Guide
Stage Pin Plugs and Connectors
15A-250V, 2 Pole - 3 Wire 
20A-125V, 2 Pole - 3 Wire
Screw and Crimp Type Contacts
ASSEMBLY AND WIRING INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND 
REGULATIONS.
WARNING: IF YOU ARE UNSURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
TO WIRE:
Recommended Cable – #12/3 through #16/3 Hard Usage Cable (SOOW, STOW, STOOW, SJOOW, SJTOW, SEOOW, etc.)
Screw and Crimp Type Contacts:
1.  WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST 
THAT POWER IS OFF BEFORE WIRING!
2.  For Screw Type Devices: 
A) Strip cable jacket back approximately 1-1/4" (3.2 cm) from end. 
B) Strip 1/2" (1.3 cm) of insulation from each conductor.
3.  For Crimp Type Devices: 
A) Strip cable jacket back approximately 3/4" (1.9 cm) from end. 
B) Strip 1/4" (0.64 cm) of insulation from each conductor.
4A. For Screw Type Devices: Attach conductors to contacts by sliding bare conductor (#16/3 wire) into ferrule ensuring stray 
strands are contained and then conductor with ferrule into screw contact (refer to Fig. 1a). NOTE: For #12/3 and #14/3 
wire, ferrule not required.
4B.  For Crimp Type Devices: Crimp appropriate lugs (for wire size as marked on crimp lug) onto conductors ensuring stray strands 
are contained within the size of the lug being used (refer to Fig. 1b). 
NOTE: Use crimping tools KS Terminals model KST2000D-1322 or Izumi model 5N18.
5.  Wire the contacts/lugs per the markings on the body of the device as follows: 
125V 
N – Neutral (White wire)  G – Ground (Green wire)  H – Hot (Black wire)
6.  Tighten the brass terminal screws to 12-14 in.-lbs. of torque.
7.  Insert strain relief as shown in Fig. 3. Strain relief should hold both conductors and cable jacket or sleeving. 
NOTE: A single strain relief may be used on top or bottom.
8. 
Secure back cover using two (2) steel screws provided. Tighten screws to approximately 16 in.-lbs. of torque (refer to Fig. 2).
PK-93489-10-02-2A
2008 © Leviton Mfg. Co., Inc.
For Technical Assistance Call: 
1-800-824-3005 (U.S.A. Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship 
under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year 
period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 
North Service Road, Melville, N.Y. 11747. This warranty  excludes and  there is  disclaimed liability  for labor  for removal  of this  product or  reinstallation. This warranty  is void  if this 
product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not 
in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any 
implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. 
Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits 
or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Fig 1a Fig 1b Fig 2
Fig 3
Male Screw Contact
Contact mâle à visser
Contacto de
tornillo macho
Wire Ferrule (for #16/3)
Ferrule (calibre 16/3)
Virola del conductor (para #16/3)
Female Screw Contact
Contact femelle à visser
Contacto de
tornillo hembra
Crimp Lug
Borne
Aleta de engarce
Male Crimp Contact
Contact mâle à sertir
Contacto de 
engarce macho
Female Crimp Contact
Contact femelle à sertir
Contacto de 
engarce hembra
Male Screw
Contacts
(shown)
Contacts
mâles à visser
(illustrés)
Contacto de 
tornillo macho 
(Se muestra) 
Front Cover
Couvercle avant
Cubierta Frontal
Back Cover
Couvercle arrière
Cubierta posterior
Main Body Housing
Corps
Cuerpo principal
Strain Relief (2)
Détendeur (2)
Protector
contra tirones (2)
No Strain Relief inserted
.601" (max. OD) - 
.525" (min. OD)
Aucun détendeur
15,265 mm (DE max.) -
13,335 mm (DE min.)
Sin protector contra tirones
.601" (Máx. OD)
.525" (Mín. OD)
 2 Strain Reliefs inserted
.350" (max. OD) -
.325" (min. OD)
Aucun détendeur
8,890 mm (DE max.) -
8,255 mm (DE min.)
Sin protector contra tirones
.350" (Máx. OD)
.325" (Mín. OD)
Strain Relief inserted
.500" (max. OD) -
.360" (min. OD)
Aucun détendeur
12,700 mm (DE max.) -
9,144 mm (DE min.)
Sin protector contra tirones
.500" (Máx. OD)
.360" (Mín. OD)
ENGLISH