Installation Manual
TEMPORARY POWER BOX
Installation Instructions
WARNINGS AND CAUTIONS:
• TO AVOID FIRE, SHOCK OR DEATH; UNPLUG CORD and TURN OFF POWER at circuit
breaker or fuse and test that power is off before installing, removing or servicing device!
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult an electrician.
• Use these devices with copper or copper clad wire only.
Receptacle Mounting to 2 Gang Rubber Box
1. Select appropriate cover for receptacle per chart below.
2. For Wet Locations Only: Remove the appropriate perforated cut-outs from the
gasket, remove film, and affix to back of cover. Refer to diagram 2.
3. Mount wired receptacle to cover as shown in diagram 3, using mounting screws
provided. NOTE: For Decora
®
devices, use provided mounting screws with nuts and
mount device to cover.
4. Place cover/receptacle assembly onto rubber box in position as shown in diagram.
Use (6) mounting screws provided to fasten cover assembly to rubber box. DO NOT
overtighten mounting screws. After tightening mounting screws, ensure that cover is
flush to rubber box.
NOTE: Tamper Resistant GFCI receptacles are not compatible with Decora
®
flip lids.
Single and Double Gang Box Wiring Instructions
WARNING: TO AVOID FIRE, SHOCK OR DEATH; UNPLUG CORD and TURN OFF POWER at circuit breaker or fuse and test that power is off before installing, removing or servicing device!
1. Install Cable Strain Relief Bushing(s) onto rubber box and torque Lock nut as follows: 1/2" NPT and 1" NPT torque 45-55 in-lbs.
2. Remove Tightening nut from bushing.
3. Strip no less than 6" of the cord cable jacket. DO NOT cut wire insulation.
4. Feed stripped length of cord through Tightening nut and bushing.
5. Torque Tightening nut as follows: 1/2" NPT and 1" NPT torque 45-55 in-lbs.
6. Strip conductors and install receptacle per installation instructions provided with receptacle.
NOTE:
For feed-through requirements, install Cable Strain Relief Bushings on both sides of box as described above and splice conductors as per code requirements.
Tightening nut
Écrou de serrage
Tuerca de ajuste
Strain relief bushing
Manchon détendeur
Buje del protector
contra tirones
Lock nut/Contre-écrou/Tuerca de fijación
Box
Boîte
Caja
Cover
mounting screw
V
is de montage du
couvercle
Tornillo de
montaje de la
cubierta
3
4
Strap "ears"
Oeillets de la bride
Orejas de la ménsula
Center tab
Patte centrale
Pestaña del centro
NOTE: Use chart below to identify the 1 Gang Box
needed for your application:
LEVITON 1 GANG POWER BOXES
3.375
3.375
3.375
3.375
4.375
4.375
4.375
4.375
A
3.900
3.900
3.900
3.900
3.900
3.900
3.900
3.900
B
2.500
2.500
2.500
2.500
2.500
2.500
2.500
2.500
C
1 Gang Standard
(for 0.23 - 0.542 Cable)
1 Gang Deep
(for 0.23 - 0.542 Cable)
1 Gang Std. Feed Through
(for 0.23 - 0.542 Cable)
1 Gang Deep Feed Through
(for 0.23 - 0.542 Cable)
1 Gang Standard
(for 0.59 - 1.00 Cable)
1 Gang Deep
(for 0.59 - 1.00 Cable)
1 Gang Std. Feed Through
(for 0.59 - 1.00 Cable)
1 Gang Deep Feed Through
(for 0.59 - 1.00 Cable)
Description
3059-01Y
3059-01E
3059F-01Y
3059F-01E
3059-02Y
3059-02E
3059F-02Y
3059F-02E
3099-01Y
3099-01E
3099F-01Y
3099F-01E
3099-02Y
3099-02E
3099F-02Y
3099F-02E
Catalog no.
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Color
Dimension (inches)
Tightening nut
Écrou de serrage
Tuerca de ajuste
Lock nut/
Contre-écrou/Tuerca de fijación
Box
Boîte
Caja
Strain relief bushing
Manchon détendeur
Buje del protector
contra tirones
NOTE: Use chart below to identify the 2 Gang Box
needed for your application:
A
C
B
A
C
B
LEVITON 2 GANG POWER BOXES
5.100
5.100
4.220
4.220
5.100
5.100
A
5.655
5.655
5.655
5.655
5.655
5.655
B
4.655
4.655
4.655
4.655
4.655
4.655
C
2 Gang Standard
(for 0.23 - 0.542 Cable)
2 Gang Standard
(for 0.59 - 1.00 Cable)
2 Gang Std. Feed Through
(for 0.23 - 0.542 Cable)
2 Gang Std. Feed Through
(for 0.59 - 1.00 Cable)
2 Gang Angled
(for 0.23 - 0.542 Cable)
2 Gang Angled
(for 0.59 - 1.00 Cable)
Description
3200-01Y
3200-01E
3200F-01Y
3200F-01E
3300-01Y
3300-01E
3300-02Y
3300-02E
3200-02Y
3200-02E
3200F-02Y
3200F-02E
Catalog no.
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Yellow
Black
Color
Dimension (inches)
PK-93660-10-02-0D
LEVITON 2 GANG POWER BOX COVERS
(2) Blank
Cat. no. 3265
(2) Duplex
Cat. no. 3260
(1) 1.56 dia.
opening
(1) Duplex
Cat. no. 3262
(1) 1.56 dia.
opening
(1) Blank
Cat. no. 3261
(2) 1.56 dia.
opening
Cat. no. 3263
(2) Duplex
flip lid
Cat. no. 3260W
(2) Decora
flip lid
Cat. no. 3251W
(1) Blank,
(1) Decora
flip lid
Cat. no. 3241W
(1) 1.56 dia.
opening flip lid
(1) Duplex flip lid
Cat. no. 3262W
(1) 1.56 dia.
opening flip lid,
(1) Blank
Cat. no. 3261W
(2) 1.56 dia.
opening flip lid
Cat. no. 3263W
(2) Decora
Cat. no. 3251
(1) Blank,
(1) Decora
Cat. no. 3241
1
4
3
Device
mounting
screw
V
is de montage
du dispositif
To
rnillo
de montaj
e
Cover mounting screw
Vis de montage
du couvercle
Tornillo de montaje
de la cubierta
Receptacle Mounting to 1 Gang Rubber Box
1. Select appropriate cover for receptacle per chart below.
2. For Wet Locations Only: Remove the appropriate perforated cut-outs from the
gasket, remove film, and affix to back of cover. Refer to diagram 2.
3. Remove strap mounting screws from receptacle and discard. For a Duplex device
trim the mounting strap by removing the 4 "ears". For a Decora
®
device remove the
"4" ears and "2" center tabs as shown in diagram 3.
4. Place wired receptacle in the mounting position as shown in diagram 4.
5. Use mounting screws provided to fasten cover and receptacle to rubber box. DO
NOT overtighten mounting screws. Ensure that cover is flush to rubber box.
NOTE: For a heavy duty installation, drill out (4) start holes located at corners on back of
covers. Fasten cover to rubber box using (6) mounting screws provided.
NOTE: Tamper Resistant GFCI receptacles are not compatible with Decora
®
flip lids.
For GFCI receptacle applications, use 1 gang deep box only.
Receptacle cover
Couvercle de prise
Cubierta de receptáculo
Side with adhesive/Côté adhésif
Lado con el adhesivo
Cover gasket
Joint d’étanchéité
Empaquetadura
de la cubierta
Perforated areas
Zones perforées
Areas perforadas
Duplex or Decora
®
cover
Couvercle double ou Decora
MD
Cubierta Doble o Decora
®
For 1 gang single receptacle cover
Couvercle pour une prise simple
Cubierta para receptáculo de una unidad
For 1 gang duplex and Decora
®
cover
Couvercle pour une prise Decora
MD
ou double
Cubierta Doble o Decora
®
para una unidad
2
For 2 gang single receptacle cover
Couvercle pour une prise à deux dispositifs
Cubierta para receptáculo de dos
For 2 gang duplex and Decora
®
cover
Couvercle pour une prise Decora
MD
ou double
Cubierta Doble o Decora
®
para una unidad
Receptacle cover
Couvercle de prise
Cubierta de receptáculo
Side with adhesive/Côté adhésif
Lado con el adhesivo
Cover gasket
Joint d’étanchéité
Empaquetadura
de la cubierta
Perforated areas
Zones perforées
Areas perforadas
Duplex or Decora
®
cover
Couvercle double ou Decora
MD
Cubierta Doble o Decora
®
2
Blank
Cat. no. 3054
Decora
Cat. no. 3060
Decora flip lid
Cat. no. 3061
Duplex
Cat. no. 3051
1.39 dia. opening
Cat. no. 3052
1.39 dia. opening
flip lid
Cat. no. 3057
Duplex flip lid
Cat. no. 3056
1.56 dia. opening
Cat. no. 3055
1.56 dia. opening
flip lid
Cat. no. 3058
LEVITON 1 GANG POWER BOX COVERS
1
Compression Nut
Écrou flottant
Tuerca de compresión
Mesh
Filet
Malla
Cable
Câble
Cable
Grommet
Bague
Ojal
Cable Grip Body
Corps du manchon
Cuerpo de agarradera
de cable
Power Box
Boîte d’alimentation
Caja de Energía
Lock Nut/Contre-écrou
Tuerca de
Seguridad
1. Slide compression nut over cable. Compress mesh and slide over cable. Slide grommet over cable.
2. Secure cable grip body to power box using lock nut. Torque 45-55 in-lbs for 1/2" NPT and 1" NPT.
3.
Slide grommet into cable grip body and lay mesh flat against grommet. NOTE: Cable jacket may have to be
stripped to pass through body. Ensure jacket is completely covered by grommet when assembled.
4. Tighten compression nut onto cable grip body. Smooth mesh onto cable eliminating slack.
Optional Installation using Wire Mesh Strain Relief Grips
Autre type d’installation utilisant des filets détendeurs
Instalación Opcional usando Agarraderas Protectoras de Malla de Alambre
1. Glisser l’écrou flottant, le filet comprimé et la bague sur le câble.
2. Fixer le corps du manchon sur la boîte d’alimentation en serrant le contre-écrou à un couple de 45-55 po-lb (filetage NPT de 1 ou de 1/2 po).
3. Glisser la bague dans le corps du manchon et poser l’extrémité du filet contre la bague.
REMARQUE : il pourrait être nécessaire de dégainer le câble pour permettre le passage dans le corps.
On doit s’assurer que la gaine est entièrement couverte par la bague une fois l’assemblage terminé.
4. Serrer l’écrou flottant sur le corps du manchon. Tendre le filet le long du câble en aplatissant tous les plis.
1. Deslice la tuerca de compresión sobre el cable. Comprima la malla y deslícela sobre el cable. Deslice la arandela sobre el cable.
2. Asegure el cuerpo de la agarradera de cable a la caja de alimentación usando la tuerca de seguridad. Use una presión de 45 a 55
in-lbs para tuercas NPT de 12.7 mm (1/2") y NPT de 25.4 (1’).
3. Deslice la arandela en el cuerpo de la agarradera del cable y que la malla quede plana contra el ojal. NOTA: El forro del cable debe
estar pelado para pasar a través del cuerpo. Asegure que el forro esté totalmente cubierto por la arandela cuando ensamble.
4. Apriete la tuerca de compresión sobre el cuerpo de la agarradera del cable. Alise la malla eliminando el cable flojo.
WEB VERSION