Instructions / Assembly

INSTALLATION INSTRUCTIONS ENGLISH
PK-A3059-10-02-0A
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton Manufacturing of Canada Ltd to the attention of the Quality
Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
IF YOU ARE UNSURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.
USE THIS DEVICE WITH COPPER OR COPPER CLAD WIRE ONLY.
INSTALLATION
1. Connect wires per appropriate WIRING DIAGRAM, using one of the wiring methods below.
2a. To Side Wire: Remove insulation approx. 3/4" (1.9 cm). Loop wires clockwise 3/4 turn around terminal screws. Firmly tighten screws over wire loops. NOTE: Side wire terminal
screws accept up to #12 AWG copper or copper clad wire.
2b. To Back Wire: Remove insulation per strip gauge on device approx. 1/2" (1.3 cm). Insert straight wires under clamps of appropriate terminal screws. Tighten screws firmly.
NOTE: Back wire terminal screws accept up to #10 AWG copper or copper clad wire.
3. Mount device using long mounting screws. Attach wallplate (not included).
4. Restore power at circuit breaker or fuse. Installation is complete.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only) www.leviton.com © 2014 Leviton Mfg. Co., Inc.
SINGLE POLE SWITCH
Cat. No. A1221 - Rated: 20A-120/277VAC
INTERRUPTEUR UNIPOLAIRE
Nº de cat. A1221 - Valeurs nominales : 20 A-120/277 V c.a.
INTERRUPTOR UNIPOLAR
No. de Cat. A1221 - Capacidad: 20A-120/277VCA
3-WAY SWITCH
Cat. No. A1223 - Rated: 20A-120/277VAC
INTERRUPTEUR À 3 VOIES
Nº de cat. A1223 - Valeurs nominales : 20 A-120/277 V c.a.
INTERRUPTOR DE 3 VIAS
No. de Cat. A1223 - Capacidad: 20A-120/277VCA
Line Hot (Black)
Ligne actif (noir)
Linea Fase (Negro)
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
3-Way Switch
Interrupteur à 3 voies
Interruptor de 3 Vías
Common Terminal (Black screw)
Terminal Commun (Vis noir)
Terminal Común (Tornillo Negro)
Travelers (Brass screw)
Cavaliers (Vis laiton)
Viajeros (Tornillo Laton)
Single Pole Switch
Interrupteur unipolaire
Interruptor Unipolar
3-Way Switch
Interrupteur à 3 voies
Interruptor de 3 Vías
1
1
1
2
2
2
Load
Charge
Carga
Line Hot (Black)
Ligne actif (noir)
Linea Fase (Negro)
Black
Noir
Negro
Black/Noir/Negro
Neutral (White)
Neutre (Blanc)
Neutro (Blanco)
Ground
(Green Screw)
Terre
(vis verte)
Tierra
(Tornillo Verde)
Ground
(Green Screw)
Terre
(vis verte)
Tierra
(Tornillo Verde)
Ground
(Green Screw)
Terre
(vis verte)
Tierra
(Tornillo Verde)
Load
Charge
Carga
LIMITED TEN YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for ten years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. For
details and to submit a concern, please visit www.leviton.com or call 1-800-824-3005. This warranty excludes claims related to the antimicrobial properties of this product.
This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an
improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or
instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required
by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to ten years. Leviton is not liable
for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay
or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
ANTIMICROBIAL TREATED
This product is made with silver ions embedded into the material that inhibits the ability of microorganisms and bacteria to grow, therefore allowing the device to continually clean
itself between normal cleaning. The antimicrobial material being used is EPA registered and tested to JIS Z 2801.
Antimicrobial Efficacy: This product is produced by incorporating silver ions (Ag+) as the antimicrobial agent into the surface exposed to touch when installed to protect it. This
treated material has proven to show a consistent [3 log (>99.9%)] microbial reduction rate against a broad range of bacteria under the JIS Z 2801 test protocol.
Care and use: Standard daily proper hygiene and cleaning procedures must be maintained. Facilities must maintain the product in accordance with their cleaning routine. The
antimicrobial protection in this product is a supplement to and not a substitute for regular cleaning. Practices related to cleaning and disinfecting must be maintained.
This surface may be subject to recontamination. The level of bacteria at any particular time will depend on frequency and timing of recontamination.
In order to have proper antimicrobial protection, this product must be cleaned and maintained according to the care instructions.
DO NOT WAX, PAINT, LACQUER, VARNISH, COAT OR ENGRAVE THIS PRODUCT
Testing illustrates that cleaning with the following chemicals have no negative effect on the antimicrobial additive: Oxivir (0.5% Hydrogen Peroxide) solution, Virex (n-Alkyl Dimethyl
Benzyl Ammonium Chloride), Dispatch (Sodium Hypochlorite stabilized bleach solution), Isopropyl Alcohol.
ANTIMICROBIAL TREATED
PRODUIT ANTIMICROBIEN
TRATADO CON AGENTES ANTIMICROBIANOS

Summary of content (2 pages)