Instructions / Assembly

7. Connect the wires only after reading other side completely - Two cables (4 or 6 wires) entering the box
Connect the LINE cable wires to the LINE terminals:
The white wire connects to the WHITE terminal (Silver)
The black wire connects to the HOT terminal (Brass or Black)
Connect the LOAD cable wires to the LOAD terminals:
Remove the YELLOW sticker to reveal the LOAD terminals
The white wire connects to the WHITE terminal (Silver)
The black wire connects to the HOT terminal (Brass or Black)
Connect the grounding wires (only if there is a grounding wire):
Connect a 6-inch bare copper (or GREEN) 12 or 14 AWG wire to the grounding terminal on the
GFCI. If the box has a grounding terminal, also connect a similar wire to the grounding terminal
on the box. Connect the ends of these wires to the LINE or LOAD cable's bare copper (or
GREEN) wire using a wire connector. If these wires are already in place, check the connections.
Complete the installation:
Fold the wires into the box, keeping the grounding wire away from the WHITE and HOT
terminals. Screw the receptacle to the box and attach the faceplate.
Go to step 8.
DI-000-ARFBF-02A© 2013 Leviton Mfg. Co., Inc.
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is
free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to
correct such defects by repair or replacement, at its option. For details visit www.leviton.com or call 1-800-824-3005. This warranty excludes
and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or
in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or
not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness
for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential
damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this
warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
RESET
RESET
ON
OFF
TEST
TEST
RESET
RESET
ON
OFF
TEST
TEST
RESET
RESET
ON
OFF
TEST
TEST
TROUBLESHOOTING
Turn the power OFF and check the wire connections against the wiring diagram. Make sure that there
are no loose wires or loose connections. Start the test from the beginning of step 8 if you rewired any
connections to the AFCI.
For Side wire -
Loop clockwise 2/3 of the
way around screw
For Back wire -
Insert bare wire fully and
tighten terminal clamp on
conductor ONLY
Black
Black
White
White
WHITE WIRE
HOT WIRE
LOAD
LINE
LINE cable brings
power to the AFCI
Electrical
Box
Wire
Connector
Grounding connection
to box (if box has a
grounding terminal)
Wire
3/4" (1.9 cm)
Back Wire:
About Wire Connections:
Side Wire:
LOAD cable feeds
power to other
receptacle(s)
WHITE WIRE
HOT WIRE
LOAD
LINE
Wire
5/8" (1.6 cm)
This product is covered by US Patent Nos. 6,040,967; 6,088,205; 6,282,070;
6,381,112; 6,433,978; 6,437,953; 6,639,769; 6,646,838; 6,657,834; 6,788,173;
6,944,001; 7,336,458; 7,400,479; 7,463,124; 7,697,252; 7,907,371; 8,054,595;
8,130,480 and corresponding foreign patents.
SmartlockPro is a Trademark of Leviton Manufacturing Co., Inc. registered
in the United States, Canada, Mexico and China.
General Information
RatingsCat. No.
AFRBF
20A-125V AC, 60Hz
Blank Face AFCI
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton
Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire
(Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
8. Test your work
Why perform this test?
If you miswire the AFCI it may not mitigate the effects of arcing faults due to
unintentional arcing in a circuit.
If you mistakenly connect the LINE wires to the LOAD terminals, the AFCI
will not reset and will not provide power to either the AFCI face or any
receptacles fed from the AFCI.
Procedure:
(a)
This AFCI is shipped from the factory in the tripped condition and cannot
be reset until it is wired correctly and power is supplied to the device.
Turn the power ON at the service panel. Ensure that the AFCI is still in the
tripped condition by pressing the TEST button. If the indicator light on the
AFCI face is ON go to the Troubleshooting section because LINE and LOAD
wiring connections have been reversed. You will not be able to RESET the
AFCI in this condition.
(b) Press the RESET button fully. If the Indicator Light turns ON, the AFCI
has been installed correctly. If the AFCI cannot be reset, go to the
Troubleshooting section.
(c) Press the TEST button, then plug a lamp or radio into surrounding
receptacles to see which one(s), in addition to the AFCI, lost power when
you pressed the TEST button. DO NOT plug life saving devices into any
of the receptacles that lost power. Place a "AFCI PROTECTED OUTLET"
sticker on every receptacle that lost power, then press the RESET button to
reset the AFCI.
(d) Press the TEST button (then RESET button) every month to assure proper
operation. If the Indicator light does not go out and come back on or if the AFCI cannot be
reset, then it must be replaced.