FAQ
19
Available in 15 or 20 Amp, 125 volt, features self-test
circuitry and slim design. For Residential/Commercial
applications, back and side wired.
• Weather-resistant with stainless steel
strap and screws, cold impact resistant
face and button
• SAFE — Delivers continuous ground
fault protection
• SELF TESTING — Automatically self-tests
to ensure it can respond to ground fault
• SIMPLE — Status indicator light
provides simple, intuitive feedback
Material taken from the National Electric Code
®
is reprinted with permission
from NFPA 70
®
, 2023 edition. National Electrical Code
®
, Copyright 2022,
National Fire Protection Association, Quincy, MA. All rights reserved.
New
210.8(D) GFCI Protection for
Specific Appliances
Change Summary
• GFCI protection is required for the branch circuit or
outlets supplying appliances. The appliances are put
in list format.
NEC
®
Text
Article 210 Branch Circuits Not Over 1000 Volts ac, 1500
Volts dc, Nominal
210.8 Ground-Fault Circuit-Interrupter Protection
for Personnel.
(D) Specic Appliances. GFCI protection shall be provided
for the branch circuit or outlet supplying the following
appliances rated 150 volts or less to ground and 60 amperes
or less, single- or 3-phase:
(1) Automotive vacuum machines
(2) Drinking water coolers and bottle ll stations
(3) High-pressure spray washing machines
(4) Tire ination machines
(5) Vending machines
(6) Sump pumps
(7) Dishwashers
(8) Electric ranges
(9) Wall-mounted ovens
(10) Counter-mounted cooking units
(11) Clothes dryers
(12) Microwave ovens
Expert Analysis
A revision has been made to clarify that GFCI protection
continued on page 20
Cat. No.
GFRW2-W