Install Instructions

Single Pole (One location) or 3-Way (Multi-location)
Universal Incandescent, CFL or LED Dimmer
Cat. No. DDL06-1LZ, 600W, 300W LED/CFL (Lighted)
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
PK-A3127-10-00-2A
TOOLS NEEDED TO INSTALL YOUR DIMMER
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity
may be required. Refer to the chart for maximum load per dimmer.
NOTE: No derating is required for LED or CFL bulb applications.
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a
multi-device application, proceed as follows:
INSTALLING DIMMER BY ITSELF
OR WITH OTHER DEVICES
Changing the color of your Dimmer:
Your device may include color options. To change color of the face
proceed as follows:
1
2
Insert top tabs and
press in bottom tabs
to attach
Push in sides at bottom
tabs and pull outward to
release
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
More than 2 Devices
500W
Two Devices
500W
Single
600W
Load
Incand
INTRODUCTION
The next generation of lighting control technology is here with the new
Decora
®
Digital Dimmer. The Decora
®
Digital Dimmer is Universal and
compatible with LED, CFL or Incandescent bulbs.
Decora
®
Digital Devices are ideal for living rooms, bedrooms, kitchens,
dining rooms, home offices, outdoor lighting or anywhere full control of
lighting is desired.
Soft fade ON/OFF
ON/OFF LED and Brightness level LED
Three way communication
Ease of installation – No new wiring
FEATURES
WARNINGS AND CAUTIONS:
• TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING!
TO AVOID FIRE, PERSONAL INJURY OR PROPERTY DAMAGE, DO NOT install to control a receptacle, a motor- or a transformer-operated appliance.
To be installed and/or used in accordance with electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
The
Decora
®
DDL06 dimmer is not compatible with standard 3-Way or 4-Way switches. It must be used with a
Decora
®
digital remote for multi-location control,
such as the DD00R-DL
.
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).
WARNINGS AND CAUTIONS:
Dimmer may feel warm to the touch during normal operation.
Recommended minimum wall box depth is 2-1/2".
Use this device WITH COPPER OR COPPER CLAD WIRE ONLY.
Use with compatible dimmable LED, CFL or incandescent bulbs only. For a list of compatible LED and CFL bulbs refer to www.leviton.com.
When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL or incandescent. Using the same make/model of each bulb will enhance
dimmer performance.
Step 4b
WIRING MATCHING REMOTE
(wall box with Line Hot connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The matching remote must be installed in a wall box with a Line
Hot connection and a Neutral connection. A Neutral wire to the matching
remote needs to be added as shown. If you are unsure about any part of
these instructions, consult an electrician.
NOTE: Maximum wire length from dimmer to all installed remotes cannot
exceed 300 ft (90m).
Green or bare copper wire in wall box to Green terminal screw.
Line Hot (common) wall box wire identified (tagged) when removing old
switch and First Traveler to remote terminal screw marked "BK".
Second Traveler wall box wire from dimmer to remote terminal screw
marked "YL/RD" (note wire color). This traveler from the remote must
go to the terminal screw on the dimmer marked "YL/RD".
Line Neutral wall box to remote terminal screw marked "WH".
WIRING DIMMER
(wall box with load connection):
Connect wires per WIRING DIAGRAM as follows:
NOTE: The dimmer must be installed in a wall box that has a Load
connection. The dimmer also requires a ground connection.
Green or bare copper wire in wall box to Green terminal screw.
Load wall box wire identified (tagged) when removing old switch to
dimmer terminal screw marked "RD".
First Traveler Line Hot to dimmer terminal screw marked "BK".
Remove Red insulating label from terminal screw marked "YL/RD".
Second Traveler wall box wire (note color as above) to dimmer terminal
screw marked "YL/RD". This traveler from the dimmer must go to the
terminal screw on the remote marked "YL/RD".
NOTE: To synchronize LEDs between a Decora
®
digital remote and the
Decora
®
DDL06 dimmer, a dim up or dim down command must be pressed
on the remote.
Proceed to Step 5.
Hot (Black)
Neutral (White)
Dimmer
Matching Remote (w/LEDs)
YL/RD
RD
YL/RD
WH BK
BK
Black
White
Line
120VAC, 60Hz
Green
Ground
Green
Ground
Load
3-Way Wiring with DD00R Matching Remote
(with LED) Application:
DimmerMatching Remote (with LED)
Terminal
Screw
marked
Black
(BK)
Terminal
Screw marked
Red (RD)
Terminal
Screw
marked
Yellow/
Red
(YL/RD)
Terminal
Screw marked
Red (RD)
2
3
5
Neutral to Terminal
Screw marked
White (WH)
2
3
5
WH
BK
RD
YL/RD
BK
RD
YL/RD
1
4
4
1
T
erminal
Screw
marked
Black
(BK)
T
erminal
Screw
marked
Yellow/
Red
(YL/RD)
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
NOTE: The DDL06 dimmer requires a ground connection.
Green or bare copper wire in wall box to Green dimmer terminal screw.
Line Hot wall box wire to Black dimmer terminal screw.
Load wall box wire to Red dimmer terminal screw.
Yellow/Red dimmer terminal screw should have Red insulation label
affixed.
NOTE: If insulating label is not afficed to Yellow/Red dimmer terminal
screw, use electrical tape to cover.
Proceed to step 5.
For non-standard wiring applications, refer
to Wire Connector and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
Dimmer
Insulating
Label
Black
Load
Hot (Black)
BK
Line
120 V
AC,
60Hz
Neutral (White)
RD
YL/RD
White
Green
Ground
Terminal
Screw marked
Black (BK)
Terminal
Screw marked
Red (RD)
Terminal Label:
Use terminal for 3-way or more applications only.
For single-pole applications, DO NOT remove label.
Terminal
Screw marked
Yellow/Red
(YL/RD)
2
4
BK
RD
YL/RD
1
3
Single Pole Wiring Application:
Step 4a
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove insulation from each wire in the wall box as shown.
For Single-Pole Application, go to Step 4a.
For 3-Way Matching Remote (no LEDs) Application, go to Step 4b.
Side Wire Connection
Side wire terminals accept
#14-12 AWG solid copper
wire only.
Back Wire Connection
Back wire openings accept
#14-12 AWG solid copper
wire only.
IMPORTANT: For 3-Way applications, note that one of the screw terminals
from the old switch being removed will usually be a different color (Black)
or labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and remote wall box.
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power
is off before wiring!
Step 1
Step 2
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any
of these configurations, consult an electrician.
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
3-Way
1. Line or Load
(see important
instruction)
2. Neutral
3. Ground
4. First Traveler –
note color
5. Second
Traveler – note
color
2
4
1
5
3
Preparing and connecting wires:
This dimmer can be wired using side wire terminal screws or
through backwire openings. Choose appropriate wire stripping
specifications accordingly.
Step 3
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Restore power at circuit breaker
or fuse.
Press pad until locator light is OFF.
Lights should turn ON. If lights do
not turn ON, press the TOP half of
the DIM/BRIGHT Bar until the lights
brighten.
If lights still do not turn ON, refer to
the TROUBLESHOOTING section.
Testing your Dimmer prior to mounting
in wall box:
Step 5
Position all wires to provide
room in outlet wall box for
device.
Ensure that the word “TOP” is
facing up on device strap.
Partially screw in mounting
screws in wall box mounting
holes.
NOTE: Dress wires with a bend
as shown in diagram in order to
relieve stress when mounting
device.
Dimmer Mounting:
TURN OFF POWER AT
CIRCUIT BREAKER OR FUSE.
Step 6
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
Installation may now be completed by
tightening mounting screws into wall
box. Attach wallplate.

Summary of content (3 pages)