Instructions / Assembly

Identifying your wiring application
(most common):
NOTE: If the wiring in the wall box does not resemble any of
these configurations, consult an electrician.
QUIET FAN SPEED CONTROL
Single Pole or 3-Way
Cat. No. DSF
Ø
1 – Ceiling Fan 1.5A
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Step 3
Step 2
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is
off before wiring or servicing fixture!
Step 1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
NOTE: For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black) or
labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the Fan Speed Control wall box and 3-way
switch wall box.
Preparing and connecting wires:
Strip gage
Cut
(if necessary)
5/8"
Make sure that the ends of the wires from the
wall box are straight (cut if necessary).
Remove 5/8" (1.6 cm) of insulation from each
wire in the wall box (shown).
For Single-Pole Application, go to Step 4a.
For 3-Way Application, go to Step 4b.
Single-Pole Wiring Application:
Step 4a
3-Way
1. Line or Load (See note below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
DI-000-DSF01-02A
NOTE: Use check boxes when Steps are completed.
3
2
4
1
5
3
2
1
4
Black
Control
Lead
3
2
1
4
Fan Speed
Control
Green
Control
Lead
Red
Control
Leads
Cap with
Wire Connector
Green
Ground
BlackRed
Red
Hot (Black)
Neutral (white)
Line
120VAC, 60Hz
Fan Speed Control
NOTE: There is NO derating
necessary for multi-gang installations
of this Fan Speed Control.
Tools needed to install your Fan Speed Control
Changing the color of your Fan Speed Control
If a color change kit is provided with your device, proceed with the following
step before wiring the device if you need to change the color. Otherwise,
proceed with the "Installing your Fan Speed Control" section.
Installing your Fan Speed Control
Slotted/Philips Screwdriver Electrical Tape Ruler
Pliers Pencil Cutters
Slide
Bar
Alignment
Arrow
Insert top tabs of the
color kit into the slots on
the top of the fan control.
Then press the bottom
of the color kit in until it
snaps into place.
Press the side of the
color kit at either bottom
tab and pull forward to
release.
Align slide bar with
alignment arrow as
shown. Move the slide
bar of the color kit to the
bottom.
REMOVE
REPLACE
Installing Control by itself or with other devices
WARNINGS AND CAUTIONS:
For use on ceiling paddle fans with split-capacitor or shaded pole motors only. Please refer to manufacturer’s
instructions or rating label on the motor to confirm type. Use with any other types of motors or equipment may cause
overheating and/or damage to the motors or equipment.
Use only one (1) Fan Speed Control per load. The switch(es) will turn ON the fan at the speed level selected
at the control.
To avoid overheating and possible damage to this device and other equipment, DO NOT install to control a
receptacle, fluorescent lighting, a motor or a transformer-operated appliance other than appropriate ceiling fans
.
WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that power is off
before wiring or servicing fixture!
TO AVOID FIRE, SHOCK, OR DEATH: this control is to be used with ceiling fans that are rated 120VAC, total load
1.5 amperes maximum.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
Use this device with copper or copper clad wire only.

Summary of content (2 pages)