User Guide

(TR) = Tamper-Resistant, (NTR) = Non-Tamper-Resistant
New SmartlockPro
®
Self-Test GFCIs
provide added protection, Slim profile.
New Underwriters Laboratories (UL) standards require
newly manufactured GFCIs to be auto-monitoring
(self-testing) by conducting an internal test to confirm
that protected power is available. This oers an
added layer of protection and is something Leviton
has always endorsed as a smart solution. As an added
benefit, our Self-Test line of GFCIs have the slimmest
profile on the market for an easy fit into any electrical
box. The combination of improved safety, smaller size,
and our superior reset lockout protection make
SmartlockPro Self-Test GFCIs ideal for upgrades,
remodels or new installations. Plus, with so many
models to choose from – Standard, Tamper-Resistant,
Duplex Guide Light, Audible, Weather-Resistant and
Blank Face – it’s easy to find the perfect solution for
both residential and commercial settings.
LED Indicators
Provide simple, intuitive feedback on power and
protection status. See diagram below.
GREEN LED - NORMAL OPERATION
- GFCI has passed self-test and is providing power
RED LED - ALERT!
- Blinking - Initial self-test upon first power up
- Solid or blinking - Press TEST and RESET buttons to reset GFCI
- If GFCI will not reset OR solid or blinking red continues, replace device
NO LED - NO POWER
- GFCI in tripped state
- Press RESET button
- If GFCI will not reset, no power on the circuit
20A-125V Feed-Through
Cat. No. GFRBF
SmartlockPro Self-Test
GFCI Outlet
SmartlockPro Self-Test
GFCI with Guide Light
SmartlockPro Self-Test
Combination GFCI with Switch
SmartlockPro Self-Test
Weather-Resistant (WR) GFCI
SmartlockPro Self-Test
Blank Face GFCI
- Auto-monitoring tests exceed the UL requirement
to confirm protected power is available*
- Auto adapts by shifting to more frequent testing
if a potential problem is detected*
Self-Test Product Oering
15A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFTR1 (TR)
Cat. No. GFNT1 (NTR)
20A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFTR2 (TR)
Cat. No. GFNT2 (NTR)
- Sensor provides automatic guide light ON/OFF
function based on ambient lighting
- Unique lens design with edge-mounted LEDs
improve light dispersion
- Audible alarm sounds when GFCI trips
- Ideal in garages, basements and other locations
where daily visual checks are unlikely
15A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFTA1 (TR)
20A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFTA2 (TR)
- Saves space wherever GFCI protection and a
switch is needed
- Ideal in kitchens, bathrooms and laundry rooms
- Designed for wet and damp locations
- Features stainless steel strap and screws, UV
stabilized plastics and cold impact resistance face
15A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFWT1 (TR)
Cat. No. GFWR1 (NTR)
20A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFWT2 (TR)
Cat. No. GFWR2 (NTR)
- When downstream protection is a priority this
GFCI provides the necessary safeguards
- Common applications: for spas/tubs or mounted
indoors to provide downstream protection to an
outdoor outlet
* Applies to all self-test GFCIs.
The SmartlockPro
®
Triple Protection Advantage
Auto-Monitoring
By conducting an internal test to confirm that
protected power is available, auto-monitoring
(self-test) GFCIs oer an added layer of protection
from electrical shocks due to hazardous ground-
faults. If, during a self-test, the GFCI detects a
problem, one or more of the following will occur:
- Power will be denied (trip with the inability
to reset)
- Trip with the ability to reset, subject to
the next auto-monitoring test cycle or
repeatedly trip
- Visual and/or audible indication
Patented Reset Lockout
The Reset Lockout feature prevents reset if
a SmartlockPro GFCI is damaged and cannot
respond to a ground fault. Older model GFCIs
may allow reset even if they are no longer
providing protection.
The National Electrical Code
®
requires the installation
of GFCIs in the following areas of the home:
- Kitchens
- Bathrooms
- Laundry Rooms
- Workshops
- Basements
- Garages/Carports
- Pool Areas
15A-125V@ Outlet, 20A-125V Feed-Through
15 Amp @ 120 VAC Switch rating
Cat. No. GFSW1 (TR)
15A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFNL1 (TR)
20A-125V@ Outlet
20A-125V Feed-Through
Cat. No. GFNL2 (TR)
SmartlockPro Self-Test GFCI
with Audible Trip Alert
LED Status Indicators