Installation Guide

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for
the benefit of anyone else that this product at the time of its sale
by Leviton is free of defects in materials and workmanship under
normal and proper use for two years from the purchase date.
Leviton’s only obligation is to correct such defects by repair or
replacement, at its option, if within such two year period the
product is returned prepaid, with proof of purchase date, and a
description of the problem to Leviton Manufacturing Co., Inc.,
Att: Quality Assurance Department, 59-25 Little Neck
Parkway, Little Neck, New York 11362-2591 (In Canada send
to Leviton Mfg. of Canada Ltd., 165 Hymus Blvd., Point Claire,
(Quebec), Canada H9R 1E9). This warranty excludes and there
is disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded, misused,
opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels
or instructions. There are no other or implied warranties of any
kind, including merchantability and fitness for a particular
purpose, but if any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty, including
merchantability and fitness for a particular purpose, is limited to
two years. Leviton is not liable for incidental, indirect, special, or
consequential damages, including without limitation, damage to,
or loss of use of, any equipment, lost sales or profits or delay or
failure to perform this warranty obligation. The remedies provided
herein are the exclusive remedies under this warranty, whether
based on contract, tort or otherwise.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
Single Pole (One location) or
3-Way (Multi-location)
120VAC, 60Hz
Electronic Low-Voltage
Cat. No. IPE04-1L (Lighted)
Rated: 400VA
INSTALLATION INSTRUCTIONS
FEATURES
Leviton's Decora
®
style design Color conversion available
Minimum Brightness Adjustment ON/OFF LED indicates status of load
Large ON/OFF switch
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND
REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED
ELECTRICIAN.
WARNING: TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO
NOT INSTALL TO CONTROL A RECEPTACLE, FLUORESCENT LIGHTING, A MOTOR- OR A TRANSFORMER-
OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.
CAUTION (For Electronic Low-Voltage Only):
1. USE WITH ELECTRONIC LOW-VOLTAGE TRANSFORMERS ONLY. DO NOT USE TO CONTROL A MAGNETIC
LOW-VOLTAGE TRANSFORMER. USE A LEVITON MAGNETIC LOW-VOLTAGE DIMMER TO CONTROL
MAGNETIC LOW-VOLTAGE TRANSFORMERS.
2. THIS DIMMER PROVIDES PROTECTION FROM OVERHEATING. AN EXCESSIVE LOAD APPLIED TO THE DIMMER
WILL CAUSE THE DIMMER TO OVERHEAT. THE EXCESS LOAD MUST BE REMOVED TO RESUME PROPER
OPERATION.
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. THE SWITCH(ES) WILL TURN THE LIGHT ON AT THE BRIGHTNESS
LEVEL SELECTED AT THE DIMMER.
2. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES
MARKED CO/ALR OR CU/AL.
MULTI-GANG INSTALLATION:
When ganging dimmers, the side sections of the mounting strap
must be removed. Use pliers to carefully bend side sections
back and forth until they break off (see Figure 1). The side
sections dissipate heat, so removing them requires a derating of
the dimmer's capacity (see chart).
MAXIMUM BULB WATTAGE (For Electronic Low-Voltage Only):
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum
bulb wattage is determined by the efficiency of the transformer in
the low-voltage lighting system. Transformer efficiencies will vary
from different manufacturers; consider 90% efficient as average.
Use the chart to determine maximum bulb wattage for typical
transformer efficiency ratings.
TO INSTALL:
1.
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST
THAT POWER IS OFF BEFORE WIRING!
2. Remove existing wallplate and switch, if applicable.
3. Remove 3/4¨ (1.9 cm) of insulation from each circuit
conductor. Make sure the ends of wires are straight.
4. Connect wires per appropriate WIRING DIAGRAM as follows:
WARNING: CONNECT AN ELECTRONIC LOW-VOLTAGE
DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE
OF AN ELECTRONIC LOW-VOLTAGE TRANSFORMER.
NOTE: Common terminal of 3-Way Switch is usually
labeled and/or BLACK. Twist strands of each lead tightly
and, with circuit conductors push firmly into appropriate wire
connector. Screw connectors on clockwise making sure no
bare wires show below the wire connectors. Secure each
connector with electrical tape.
NOTE: For single pole applications, cap one BLACK lead with
an appropriate size wire connector. Secure connector with
electrical tape.
NOTE: This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the dimming
range to suit each installation. This adjustment is preset at the factory and should require no further adjustments for most
installations. If adjustment is required proceed as follows, otherwise continue with step 8:
R
DI-000-IPE04-00A
DI-000-IPE04-00A
R
Two More than
Cat. No. Single Gang 2 Gang
IPE04-1L 400VA 350VA 250VA
MAXIMUM LOAD PER CONTROL FOR MULTI-GANG
Two More than
Rating Single Gang
2 Gang
400VA 360W 315W 225W
MAXIMUM BULB WATTAGE AT 90% EFFICIENCY
C O L L E C T I O N B Y L E V I T O N
/
/
Figure 1 - Dimmer Functions
Slider
ON/OFF
LED
ON/OFF
Push-Button
Switch
Trim Adjustment
Screw
Mounting Strap
Side Sections

Summary of content (2 pages)