Installation Guide

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such
defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York
11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied
warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this
warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
NOTE: Dimmer can be installed on either the Load or Line
side.
Green dimmer Ground lead to Green or bare copper wire
in wall box.
Black dimmer lead to tagged (common) wall box wire
identified when removing old switch.
Remove Red insulating label from Red lead.
Any Red dimmer lead to any of the remaining
wall box wires.
Remaining Red dimmer lead to remaining wall box wire.
Testing your Dimmer prior to mounting in wall
box:
Dimmer Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore Power: Restore power at circuit breaker or
fuse. Installation is complete.
OPERATION
NOTE: If using the dimmer in a 3-way application, the lights will
turn ON at brightness set on dimmer's slide control lever. The
lighting level can be controlled from either the dimmer or the
switch location.
Step 7
PK-92950-10-00-2D
Step 5b
Hot (Black)
Neutral (White)
Dimmer
3-Way Switch
Red
Black
Green
Ground
Green
Ground
Black
White
Red
Line
120/277VAC, 60Hz
Common
Terminal
(Black Screw)
Ballast
Red
Blue
Yellow
To Lamps
Primary
Side
Step 6
Step 5a
Black
Red
Neutral
Green
Ground
Red
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Black
Tag
Red
Green
Red
Neutral
Ground
Step 5b
con’t
Restore power at circuit breaker or
fuse.
Carefully holding Dimmer as
shown, move slider control lever to
highest position. Lights should turn
ON to brightest level. If lights do not
turn ON, depress push-button switch
once. Lights should turn ON to
brightest level.
If lights still do not turn ON, refer
to the TROUBLESHOOTING
section.
Installation may now be completed
by carefully positioning
all wires to provide room in wall box
for dimmer. Mount dimmer
into box with mounting screws
supplied. Attach wallplate.
ON/OFF:
Depress push-button switch to ON
position - Lights will turn ON.
Depress push-button switch to OFF
position - Lights will turn OFF.
BRIGHTEN & DIM:
Move slider control lever - Lights will
BRIGHTEN or DIM.
Insert wires
straight then twist
clockwise
Insert wires
straight then twist
clockwise
Electrical
Tape
Electrical
Tape
Step 8
Hot (Black)
Neutral (White)
Dimmer
Black
Green
Ground
Black
White
Red
Line
120/277VAC, 60Hz
Red
Insulating
Label
Ballast
Red
Blue
Yellow
To Lamps
Primary
Side
Single-Pole Wiring Application:
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
NOTE: Dimmer can be installed on either the Load or Line
side.
Green dimmer Ground lead to Green or bare copper
wire in wall box.
Black dimmer lead to any wall box wire removed
from old switch.
Red dimmer lead without insulating label to remaining
wall box wire. Proceed to Step 6.
Remaining Red dimmer lead should have Red insulation
label affixed. Proceed to Step 6.
NOTE: If insulating label is not affixed to Red lead, use a
small wire nut or electrical tape to cap off. Proceed to Step 6.
3-Way Wiring Application:
TROUBLESHOOTING
Lights Flickering
- Lamp has a bad connection.
- Wires not secured firmly with
wire connectors.
Light does not turn ON and
ON/OFF LED does not turn ON
- Circuit breaker or fuse has
tripped.
- Lamp is burned out.
- Sockets are not Rapid Start type.
- Lamp Neutral connection is not wired.
NOTE: If further information is needed in identifying the HOT wire
in a 3-Way application, go to
Leviton's website at www.leviton.com.
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/G24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
39
31
24
21
39
20
14
33
17
11
29
14
39
31
24
21
39
20
14
33
17
11
29
14
39
31
24
21
39
20
14
33
17
11
29
14
VEZ-1T32
VEZ-1T32
VEZ-1T42
VEZ-2Q26
VEZ-132
VEZ-2S32
VEZ-3S32
VEZ-132
VEZ-2S32
VEZ-3S32
VEZ-1TTS40
VEZ-2TTS40
WIRE CONNECTOR / # OF COND.
COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #12 w/ 1 or 2 #16 or #18
1- #14 w/ 1 to 4 #16 or #18
2- #14 w/ 1 to 3 #16 or #18
For non-standard wiring
applications, refer to Wire
Nut and Connector Size Chart
Cat. No. IPX
Ø
6-1, 120V, For use with
Advance Transformer 120V Mark 10™
Powerline
Electronic Ballasts
Lamp
Max. # Ballasts/
Dimmer for Multi-gang
Two
Ganged
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/G24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
19
16
12
10
19
10
7
17
8
6
15
7
16
13
10
9
16
8
6
14
7
5
12
6
More than
2 Gang
13
10
8
7
13
7
5
11
6
4
10
5
Single
Gang
REZ-IT32
REZ-IT32
REZ-IT42
REZ-2Q26
REZ-132
REZ-2S32
REZ-3S32
REZ-132
REZ-2S32
REZ-3S32
REZ-1TTS40
REZ-2TTS40
Advance
Mark 10™
Powerline
Part No.
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
Cat. No. IPX1
Ø
-1, 120V, For use with
Advance Transformer 120V Mark 10™
Powerline
Electronic Ballasts
Lamp
Max. # Ballasts/
Dimmer for Multi-gang
Two
Ganged
32
26
20
17
32
17
11
28
14
9
25
12
26
21
16
14
26
13
9
22
11
8
20
10
More than
2 Gang
22
18
14
12
22
12
8
19
10
7
17
9
Single
Gang
REZ-1T32
REZ-1T32
REZ-1T42
REZ-2Q26
REZ-132
REZ-2S32
REZ-3S32
REZ-132
REZ-2S32
REZ-3S32
REZ-1TTS40
REZ-2TTS40
Advance
Mark 10™
Powerline
Part No.
Cat. No. IPX12-7, 277V, For use with
Advance Transformer 277V MarkX™
Powerline
Electronic Ballasts
Lamp
Max. # Ballasts/
Dimmer for Multi-gang
Two
Ganged
More than
2 Gang
Single
Gang
Advance
Mark 10™
Powerline
Part No.
Cat. No. IPX
Ø
6-7, 277V, For use with
Advance Transformer 277V Mark 10™
Powerline
Electronic Ballasts
Lamp
Max. # Ballasts/
Dimmer for Multi-gang
Two
Ganged
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/G24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
20
15
12
10
20
10
7
17
8
6
14
7
20
15
12
10
20
10
7
17
8
6
14
7
More than
2 Gang
20
15
12
10
20
10
7
17
8
6
14
7
Single
Gang
VEZ-1T32
VEZ-1T32
VEZ-1T42
VEZ-2Q26
VEZ-132
VEZ-2S32
VEZ-3S32
VEZ-132
VEZ-2S32
VEZ-3S32
VEZ-1TTS40
VEZ-2TTS40
Advance
Mark 10™
Powerline
Part No.