Product Brochure

1.03 (26.1)
1.69 (42.7)
1.31 (33.3)
3.27 (83.1)
2.70 (68.6)
4.21 (106.9)
3.81 (96.8)
1.32 (33.6)
15A SmartlockPro
®
Self-Test GFCI 20A SmartlockPro
®
Self-Test GFCI
1.69 (42.8 mm)
1.31 (33.3 mm)
3.81 (96.8 mm)
3.27 (83.0 mm)
2.70 (68.6 mm)
4.21 (106.9 mm)
1.03 (26.1 mm)
1.40 (35.5 mm)
GREEN LED - NORMAL OPERATION
- GFCI has passed self-test and is providing power
RED LED - ALERT!
- Blinking - Initial self-test upon first power up
- Solid or blinking - Press TEST and RESET buttons to reset GFCI
- If GFCI will not reset OR solid or blinking red continues, replace device
NO LED - NO POWER
- GFCI in tripped state
- Press RESET button
- If GFCI will not reset, no power on the circuit
Agency Standards and Compliance
Meets the latest UL requirements
UL Standard 943 Class A (GFCI) and 498 (Receptacles)
UL Listed (File #E-48380)
CSA Certified (File #LR-57811)
NOM Certified
Meets Federal Specification W-C-596G (blank face - exception)
Material Characteristics
Environmental: Flammability UL-94 V2 Rating
Operating Temperature: -35°C to 66°C
Material: Face, Thermoplastic; Body, Polycarbonate
Status Indicator Light
Leviton GFCI devices feature an LED Status Indicator Light which provides a visual
indication to the user of the status of GFCI protection. This is a convenient way
to check the level of protection at-a-glance.