Installation Guide

Page 6
Maximum number of dimmers.
This parameter must be set to reflect a number greater than or equal to the maximum number
of dimmer channels installed in the system. The factory default is 32 dimmer channels. If this
number is correct then this step may be ignored.
The maximum number of dimmers may be set as follows:
1. Make sure that the 400CP is in the program select mode as discussed.
2. Press the zone 1 increase button and the BUSY led will quit flashing.
3. Press button representing desired number of dimmers as shown in the diagram.
4. If more than 256 dimmers are required then press a second button so that the sum of the
values of the two buttons pressed will equal the desired number of dimmers.
5. The unit will exit this programming mode and the BUSY LED will start flashing again on
release of the second press, or after a few seconds if only one press was required.
SCENE 1 SCENE 2 SCENE 3 SCENE 4
SCENE 5 SCENE 6 SCENE 7 SCENE 8
LUMA-NET
408 CP
PWR BUSY
DOWN UP ADD DELETE
SCENE 1 SCENE 2 SCENE 3 SCENE 4
LUMA-NET
404 CP
PWR BUSY
DOWN UP ADD DELETE
DIMMER ASSIGNMENT MODE