Submittal
17
tiers, and penthouses with headroom height of 7.5 feet or greater. Building square
footage is measured from the exterior faces of exterior walls or from the centerline of
walls separating buildings, but excludes covered walkways, open roofed-over areas,
porches and similar spaces, pipe trenches, exterior terraces or steps, chimneys, roof
overhangs, and similar features.
.02 Building within the Scope of Standard 90.1-2001. A structure that--
(1) Is wholly or partially enclosed within exterior walls, or within exterior
and party walls, and a roof, affording shelter to persons, animals, or property; and
(2) Is not a single-family house, a multi-family structure of three stories or
fewer above grade, a manufactured house (mobile home), or a manufactured house
(modular).
.03 Conditioned Space. Any enclosed space within the building qualifying as
cooled space, heated space, or indirectly conditioned space defined as follows:
(1) Cooled Space. An enclosed space that is cooled by a cooling system
whose sensible output capacity exceeds 5 Btu per hour per square foot of floor area.
(2)
Heated Space. An enclosed space that is heated by a heating system
whose output capacity relative to the floor area exceeds 5 Btu per hour per square foot
of floor area.
(3) Indirectly Conditioned Space. An enclosed space (other than a heated
space or a cooled space) that is heated or cooled indirectly by being connected to
adjacent space(s) and that satisfies either of the following conditions:
(a) The space’s surface area that is adjacent to heated or cooled