Instructions / Assembly

FEATURES
Works with Mark 10™ or Hi-lume
®
120V (Cat.No. PE200-1) and 277V (Cat. No. PE200-7) dimmable ballasts.
NOTE: Hi-lume
®
is a registered trademark of the Lutron Electronics Co., Inc.
Low-end adjustment available for setting the minimum brightness level.
Works with any Dimensions 3200 Series Multizone Controller/Dimmer to extend load capacity on any zone.
DESCRIPTION
The Leviton Power Extender, Cat. No. PE200-1 and PE200-7, will emulate the characteristics of the dimmer that it is
connected to in terms of dimming range and resolution.
Compatibility
Box Mounted Dimmers – Must use a 120V, 600VA Mark 10™ version of the following families: Monet,
Illumatech, Sureslide, Mural, and Touch Point.
NOTE: When using Hi-lume
®
ballasts, incandescent dimmers must be used.
D3200 – Zone must be configured to work with fluorescent loads. Refer to D3200 User guide for details.
NOTE: When using Hi-lume
®
ballasts, the zone must be set for incandescent load.
Architectual SystemsWorks with all families.
NOTE: For dimmers that include a Neutral wire, the dimmer Neutral wire must be connected.
NOTE: The PE200 has a minimum level adjustment.
FCC COMPLIANCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the
equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
INSTALLATION INSTRUCTIONS
WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES
AND REGULATIONS.
WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED
ELECTRICIAN.
OTHER CAUTIONS:
1. BOTH LIGHTING FIXTURE AND CONTROLLER MUST BE GROUNDED.
2. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING LAMPS.
3. TO BE USED FOR DIMMING ONLY WITH ADVANCE MARK 10™ OR HI-LUME
®
DIMMING BALLASTS.
4. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
DEVICES MARKED CO/ALR OR CU/AL.
NOTE: The Power Extender must be installed in a 1900 Box with Raised Cover or a properly grounded metal
2-gang wall box, 3.5" (8.9 cm) deep (refer to Figure 1A and 1B). Depending on the application and the number of
connections, more space may be needed. If so, use an appropriate size box or box extension.
TO INSTALL:
1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKERS OR FUSES
AND TEST THAT POWER IS OFF BEFORE WIRING!
MORE THAN ONE CIRCUIT BREAKER CAN POWER THIS DEVICE. DISCONNECT “ALL” POWER SOURCES
BEFORE SERVICING CONTROL.
2. Remove 1/2" (1.3 cm) of insulation from each circuit conductor in wall box. Make sure that ends of conductors are
straight.
3. Connect lead wires per appropriate WIRING DIAGRAM and FIGURE 2 as follows: All connections to the output
terminals should be made using #12 AWG wire. Each power terminal can accept up to two(2) #12 wires. The
recommended installation torque is 9.0 in.-lbs. for line voltage connections.
4. Carefully position all wires to provide room in wall box for Power Extender. All Power Extenders must have 4-1/2"
spacing above and below each unit for proper ventilation and heat dissipation (refer to Figure 4).
Line voltage
wiring should be at least 6 ft. away from sound or electronic equipment wiring. Mount Power Extender
to outlet box with “TOP” facing up (refer to Figure 3).
For Wall Box Mounting: Refer to Figure 1A.
For Flush Mounting: Refer to Figure 1B.
DI-000-PE200-00B
Power Extender
Dimming Control
Fluorescent Only
Cat. No. PE200-1
Rating: 1920VA
120VAC, 50/60Hz
Cat. No. PE200-7
Rating: 3000VA
277VAC, 50/60Hz
For use with Advance Transformer Mark 10™
Powerline
or Hi-lume
®
dimming ballasts.
For more information go to www.leviton.com
INSTALLATION INSTRUCTIONS
LIMITED 5 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
workmanship under normal and proper use for five years
from the purchase date. Leviton’s only obligation is to correct
such defects by repair or replacement, at its option, if within
such five year period the product is returned prepaid, with
proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance
Department, 59-25 Little Neck Parkway, Little Neck, New
York 11362-2591 (In Canada send to Leviton Mfg. of
Canada Ltd., 165 Hymus Blvd., Point Claire, (Quebec),
Canada H9R 1E9). This warranty excludes and there is
disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
merchantability and fitness for a particular purpose, but if
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to five years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
For Panel Mounting (not shown), Proceed as follows:
a. The enclosure must be in accordance with all local and national
electrical codes.
b. Leviton DOES NOT recommend using a door to enclose the front of
a panel, since this restricts airflow to the controls.
c. If mounting multiple controls in an enclosure:
Ambient temperature within an enclosure “MUST REMAIN
BETWEEN” 32˚-104˚F (0˚-40˚C).
If not mounting in a metal enclosure, all units “MUST” be mounted in a wall box.
d. To improve heat dissipation of controls, remove the faceplate from the unit.
5. Restore power at circuit breaker or fuse.
6. Turn ON the dimmer.
7. Using the dimmer control, verify that the load DIMS and BRIGHTENS smoothly and the lamps do not flicker.
8. Attach wallplate by aligning tabs on back of plate with grooves in fins on Power Extender (refer to Figure 1A and
Figure 1B). INSTALLATION IS COMPLETE.
OPERATION
The operation of the PE200 follows the operation of the dimmer it is connected to. To operate the PE200, the
dimmer must be operated as follows:
ON: Turn ON the dimmer.
Turn OFF: Turn OFF the dimmer.
DIM: Adjust the dimmer DIM level.
BRIGHTEN: Adjust the dimmer BRIGHTNESS level.
Green LED: Illuminates when load in ON.
Air Gap: Activating the air gap on the dimmer will cause the PE200 to turn its controlled Load OFF.
CAUTION: The Power Extender will still remain powered, but it will not activate the load.
The PE200 has an air gap relay built in, therefore, the ballasts will be disconnected by an air gap when the dimmer
is OFF or the air gap control on the dimmer is activated.
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
DI-000-PE200-00B
1900 Box
Raised Cover
Mounting Screws
(4 Places)
Power
Extender
Power Extender
Wallplate
TOP
2 Gang Raised Cover
Figure 1A: Surface Mounting
1900 Box
Raised Cover
Mounting Screws
(4 Places)
TOP
2 Gang Raised Cover
Power Extender
Wallplate
Power
Extender
Figure 1B: Flush Mounting
TOP
TOP
4-1/2" (11.4 cm)
Minimum
4-1/2" (11.4 cm)
Minimum
NEUTRAL
NEUTRAL
LOAD
HOT
SWITCH
HOT
CONTROL
Figure 2: End View
Figure 3: Front View
Trim
Adjustment
TOP
Green LED
Figure 4: Front View Spacing
WEB VERSION