Instructions / Assembly

Identifying your wiring application
(most common):
NOTE: If the wiring in the wall box does not resemble any of these
configurations, consult an electrician.
LED / CFL / INCANDESCENT SLIDE DIMMER
Single Pole or 3-Way
Cat. No. DSL
Ø
6 – LED/CFL 300W (2.5A), Incandescent 600W
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Tools needed to install your Dimmer
Slotted/Philips Screwdriver Electrical Tape Ruler
Pliers Pencil Cutters
LOC
OFF
ON
AB
LOC
OFF
ON
AB
Slide
Bar
Alignment
Arrow
Step 3
Changing the color of your Dimmer
If a color change kit is provided with your device, proceed with the following
step before wiring the device if you need to change the color. Otherwise,
proceed with the "Installing Dimmer by itself or with other devices" section.
In incandescent multi-dimmer installations,
the reduction of the dimmer’s capacity is
required. Refer to the chart for maximum load
per dimmer. No derating is required for use in
dimmable CFL or dimmable LED multi-dimmer
installations.
Installing Dimmer by itself or with other devices
Step 2
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF
POWER at circuit breaker or fuse and test that power is off before
wiring or servicing fixture!
Step 1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
NOTE: For 3-Way applications, note that one of the screw terminals from the old
switch being removed will usually be a different color (Black) or labeled Common.
Tag that wire with electrical tape and identify as the common (Line or Load) in both
the dimmer wall box and 3-way wall box.
Preparing and connecting wires:
Strip gage
Cut
(if necessary)
5/8"
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove 5/8" (1.6 cm) of insulation from each wire in the wall box
(shown).
For Single-Pole Application, go to Step 4a.
For 3-Way Application, go to Step 4b.
Single-Pole Wiring Application:
Step 4a
3-Way
1. Line or Load (See note below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
DI-000-DSL06-02A
Installing your Dimmer
NOTE: Use check boxes when Steps are completed.
3
2
4
1
5
3
2
1
4
Terminal
Screw Marked
Black (BK)
Terminal
Screw Marked
Red (RD)
Terminal Label:
Use terminal for
3-way or more
applications only.
For single pole
applications,
DO NOT remove
this label.
3
2
1
4
Dimmer
Terminal
Screw Marked
Ground (GR)
Terminal Label:
Use terminal for
3-way or more
applications only.
For single pole
applications,
DO NOT remove
this label.
Green
Ground
BKRD
Hot (Black)
Neutral (white)
Line
120VAC, 60Hz
Dimmer
Insert top tabs of the
color kit into the slots on
the top of the dimmer.
Then press the bottom
of the color kit in until it
snaps into place.
Press the side of the
color kit at either bottom
tab and pull forward to
release.
Align slide bar with
alignment arrow as
shown. Move the slide
bar of the color kit to the
bottom.
REMOVE
REPLACE
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No. Load Single Two
Devices
More than 2
Devices
DSL
Ø
6 Incand. 600W 500W 500W
DSL
Ø
6 LED/CFL 300W (2.5A) 300W (2.5A) 300W (2.5A)
WARNINGS AND CAUTIONS:
When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL
or incandescent. Using the same make/model of each bulb will enhance performance.
Use only one (1) dimmer in a 3 or 4-way circuit. The switch(es) will turn the light on at the brightness level selected
at the dimmer.
To avoid overheating and possible damage to this device and other equipment, DO NOT install to control a
receptacle, a motor or a transformer-operated appliance, or any other lighting sources than those specified.
WARNINGS AND CAUTIONS:
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that power is off
before wiring or servicing fixture!
TO AVOID FIRE, SHOCK, OR DEATH: use with compatible dimmable LED and CFL bulbs, incandescent or 120V
halogen fixtures only. For a complete list of compatible LED and CFL bulbs refer to www.leviton.com/universal.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
Use this device with copper or copper clad wire only.

Summary of content (2 pages)