Instructions / Assembly

Preparing and connecting wires:
This receptacle can be wired using side wire terminal screws or
through backwire openings. Choose appropriate wire stripping
specifications accordingly.
WARNING: TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is off
before wiring!
Identifying your wiring application (most common):
NOTE: If the wiring in your wall box does not resemble any of
these configurations, consult a qualified electrician.
WARNINGS AND CAUTIONS:
TO AVOID FIRE SHOCK OR DEATH; TURN OFF POWER at circuit breaker or fuse and test that power is off before wiring!
To be installed and/or used in accordance with electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
To ensure that there is adequate room for wires, we recommend using at a minimum 3-1/2 inch deep wallboxes. For single-gang applications, this would be at a
minimum an 18-cubic inch wallbox.
WARNINGS AND CAUTIONS:
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
Maximum wire length cannot exceed 300 ft (90 m).
Use this device with copper or copper clad wire only.
Not for use with Vizia RF
®
lighting systems.
Duplex Receptacle (Top Controlled)
Scene Capable Receptacle
Cat. No. DZR15 - 15A - 125VAC, 60Hz
Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)
Electronic Low-Voltage-1800W – Fluorescent-1800VA – Supplemental-1/2 HP
INSTALLATION INSTRUCTIONS
DI-000-DZR15-02A
TOOLS NEEDED TO INSTALL YOUR RECEPTACLE
Slotted/Phillips Screwdriver Electrical Tape Pliers
Pencil Cutters Ruler
Changing the color of your Receptacle:
Your Receptacle includes three color options. The Receptacle ships with the
White frame attached. To change color of frame, proceed as follows:
INSTALLING YOUR RECEPTACLE
NOTE: Use check boxes when Steps are completed.
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&
/./&&/./&&
/./&&
/./&&
/./&&
/./&&
Step 1
2
4
3
1
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
Step 2
Single Pole Wiring Application:
Step 3
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove insulation from each wire in the wall box as shown.
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Side Wire Connection
Side wire terminals accept #14-12
AWG solid copper wire only.
Back Wire (either hole may be used)
Back wire openings accept #14-12
AWG solid copper wire only.
WIRING RECEPTACLE:
Connect wires per WIRING DIAGRAM as follows:
Green or bare copper wire in wall box to Green terminal screw.
Line Hot wall box wire to terminal screw marked "LINE".
Line Neutral wall box wire to terminal screw marked "NEUTRAL".
Proceed to Step 5.
Leviton’s Decora
®
Z-Wave
®
control components are designed to
communicate with each other via Radio Frequency (RF) to provide remote
control of your lighting. In a Z-Wave
®
network, each device is designed
to act as a router. These routers will re-transmit the RF signal from one
device to another until the intended device is reached. This ensures
that the signal is received by its intended device by routing the signal
around obstacles and radio dead spots. The Scene Capable Electronic
Receptacle is compatible with most Z-Wave
®
enabled networks, from
different manufacturers and can also be used with other devices displaying
the Z-Wave
®
logo.
WARNING:
TO AVOID FIRE, PERSONAL INJURY OR DEATH DO NOT
USE the remote for the control of high power heating appliances such
as portable heaters.
Remember to exercise good common sense when
using the Timer features of your Remote – especially when scheduling
unattended devices. There can be some unexpected consequences if
not used with care. For example, an empty coffee pot can be remotely
turned on. If that should happen, your coffee pot could be damaged from
overheating. If an electric heater is turned on by remote control while
clothing is draped over it, a fire could result. DO NOT USE the remote for
the control of high power heating appliances such as portable heaters.
• Receptacle ON/OFF
• Scene Capable
• ON/OFF LED
Two way communication
• RF reliability
Ease of installation – No new wiring
Compatible with other Z-Wave
®
enabled devices
FEATURES
INTRODUCTION
Testing your Receptacle prior to mounting in
wall box:
Receptacle Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Restore power at circuit breaker or fuse.
Locator light should turn ON.
If locator light does not turn ON, refer to the TROUBLESHOOTING
section.
Step 5
Position all wires to provide room in outlet wall box for device.
Partially screw in mounting screws in wall box mounting holes.
NOTE: Dress wires with a bend as shown in diagram in order to
relieve stress when mounting device.
Step 6
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
Neutral (Silver)
Line (Black)
Green
Ground
CONTROLLED
Push in side
at tab to release
Line up tabs and
press in sides one at a time
to attach
Step 4
CONTROLLED
Installation may now be completed by tightening
mounting screws into wall box. Attach wallplate.
NOTE: To include your dimmer into a network, contact
Leviton’s Techline at 1-800-824-3005 or visit Leviton’s
website at www.leviton.com.
WEB VERSION