Installation Guide

LED / CFL / INCANDESCENT TOGGLE DIMMER
Single Pole or 3-Way
Cat. No. TSL
Ø
6 – LED/CFL 300W (2.5A), Incandescent 600W
120VAC, 60Hz
INSTALLATION INSTRUCTIONS
Tools needed to install your Dimmer
Slotted/Philips Screwdriver Electrical Tape Ruler
Pliers Pencil Cutters
In incandescent multi-dimmer installations, the reduction of the dimmer’s
capacity is required. Refer to the chart for maximum load per dimmer.
No derating is required for use in dimmable CFL or dimmable LED
multi-dimmer installations.
Installing Dimmer by itself or with other devices
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFF
ONOFFONOFF
ONOFF
ONOFF
ONOFF
ONOFF
WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER at circuit breaker or fuse and test that power is
off before wiring or servicing fixture!
Step 1
Step 3
Preparing and connecting wires:
Strip gage
Cut
(if necessary)
5/8"
Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
Remove 5/8" (1.6 cm) of insulation from each wire in the
wall box.
For Single-Pole Application, go to Step 4a.
For 3-Way Application, go to Step 4b.
DI-000-TSL06-02A
Installing your Dimmer
NOTE: Use check boxes when Steps are completed.
3
Identifying your wiring application
(most common):
NOTE: If the wiring in the wall box does not resemble any of
these configurations, consult an electrician.
Step 2
Single Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
NOTE: For 3-Way applications, note that one of the screw terminals from
the old switch being removed will usually be a different color (Black) or
labeled Common. Tag that wire with electrical tape and identify as the
common (Line or Load) in both the dimmer wall box and 3-way wall box.
3-Way
1. Line or Load (See note below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
3
1
5
4
2
3
1
4
2
Single-Pole Wiring Application:
Step 4a
Terminal
Screw Marked
Black (BK)
Terminal
Screw Marked
Red (RD)
Terminal Label:
Use terminal for
3-way or more
applications only.
For single pole
applications,
DO NOT remove
this label.
Dimmer
Terminal
Screw Marked
Ground (GR)
3
1
4
2
BK
RD
Terminal Label:
Use terminal for
3-way or more
applications only.
For single pole
applications,
DO NOT remove
this label.
Green
Ground
Hot (Black)
Neutral (White)
Line
120VAC, 60Hz
Dimmer
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Cat. No. Load Single Two
Devices
More than 2
Devices
TSL
Ø
6 Incand. 600W 500W 500W
TSL
Ø
6 LED/CFL 300W (2.5A) 300W (2.5A) 300W (2.5A)
WARNINGS AND CAUTIONS
When multiple bulbs are used with one dimmer DO NOT mix bulb types. All bulbs shall be either LED; CFL
or incandescent. Using the same make/model of each bulb will enhance performance.
Use only one (1) dimmer in a 3 or 4-way circuit. The switch(es) will turn the light on at the brightness level selected
at the dimmer.
To avoid overheating and possible damage to this device and other equipment, DO NOT install to control a
receptacle, a motor or a transformer-operated appliance, or any other lighting sources than those specified.
WARNINGS AND CAUTIONS
TO AVOID FIRE, SHOCK, OR DEATH: TURN OFF POWER at circuit breaker or fuse and test that power is off
before wiring or servicing fixture!
TO AVOID FIRE, SHOCK, OR DEATH: use with compatible dimmable LED and CFL bulbs, incandescent or 120V
halogen fixtures only. For a complete list of compatible LED and CFL bulbs refer to www.leviton.com/universal.
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult an electrician.
Use this device with copper or copper clad wire only.
Green or bare copper wall box wire to terminal screw marked "GR".
Line Hot wall box wire to terminal screw marked "BK".
Load wall box wire to terminal screw marked "RD".
Remaining dimmer terminal screw marked "RD" should have an
insulation label affixed. DO NOT REMOVE this label in a single pole
application.
Proceed to Step 5.
Connect wires per WIRING DIAGRAM as follows:
WEB VERSION

Summary of content (2 pages)