Specification

Universal Occupancy/Vacancy Sensors
PRODUCT BULLETIN
G-8761A/A13-dp
Wiring Diagrams
Use Terminal for 3-Way
Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Hot (Black)
Neutral (White)
Red
Black
Black
White
LOAD
Line
120VAC, 60 Hz
Sensor
Green
Ground
3-Way
(Brass
Screw)
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Green
Ground
3-Way/
Brass
Common Terminal
(Black Screw)
Pigtail
Pigtail
Green
Ground
LOAD/Red
First Traveler
Second Traveler
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
First Traveler
Second Traveler
LOAD/
Red
Sensor
Sensor
Use Terminal for 3-Way
Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Hot (Black)
Neutral (White)
Red
Black
Black
White
LOAD
Line
120VAC, 60 Hz
Sensor
Green
Ground
3-Way
(Brass
Screw)
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
Green
Ground
LOAD/Red
First Traveler
Second Traveler
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
First Traveler
Second Traveler
LOAD/
Red
Sensor
Sensor
Use Terminal for 3-Way
Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Hot (Black)
Neutral (White)
Red
Black
Black
White
LOAD
Line
120VAC, 60 Hz
Sensor
Green
Ground
3-Way
(Brass
Screw)
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
Green
Ground
LOAD/Red
First Traveler
Second Traveler
Hot (Black)
Neutral (White)
LINE/Black
LOAD
Line
120VAC
60 Hz
Sensor
Green
Ground
Green
Ground
3-Way/
Brass
3-Way Switch
Common Terminal
(Black Screw)
Pigtail
Pigtail
First Traveler
Second Traveler
LOAD/
Red
Sensor
Sensor
Visit our Website at: www.leviton.com/sensors
© 2013 Leviton Manufacturing Co., Inc. All rights reserved.
Leviton Manufacturing Co., Inc.
201 North Service Road, Melville, NY 11747-3138
Telephone: 1-800-323-8920 FAX: 1-800-832-9538
Tech Line (8:30AM-7:00PM E.T. Monday-Friday): 1-800-824-3005
Ordering Information:
Description Rating (120VAC) Cat. No. Color
Relay Vacancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
300W Incand/FL Ballast,150W LED/
CFL, 1/6 HP Motor
IPV02 W, LT
Relay Occupancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
300W Incand/FL Ballast,150W LED/
CFL,1/6 HP Motor
IPS02 W, I, LT
Relay Vacancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
600W Incand/FL Ballast
150W LED/CFL, 1/6
HP Motor
IPV05 Z
Relay Occupancy Sensor, single pole,
180° Field of View, 900 sq. ft. coverage
600W Incand/FL Ballast
150W LED/CFL, 1/6
HP Motor
IPS05 Z
Occupancy Sensor, single pole or 3-Way,
180° Field of View, 900 sq. ft. coverage
600W Incand
150W LED
IPS06 W
Dimming Vacancy Sensor, single pole or 3-Way,
180° Field of View, 900 sq. ft. coverage
600W Incand
150W LED/CFL
IPVD6 Z
Dimming Occupancy Sensor, single pole or 3-Way,
180° Field of View, 900 sq. ft. coverage
600W Incand
150W LED/CFL
IPSD6 Z
Relay Vacancy Sensor, single pole or 3-Way**, 180°
Field of View, 900 sq. ft. coverage, neutral required
1800W Incand, 600W LED/CFL,
1800VA Magnetic Ballast, 1/2 HP
IPV15 Z
Relay Occupancy Sensor, single pole or 3-Way**, 180°
Field of View, 900 sq. ft. coverage, neutral required
1800W Incand, 600W LED/CFL,
1800VA Magnetic Ballast, 1/2 HP
IPS15 Z
Sensor Remote, 120VAC, Manual-ON, Auto-OFF For use with IPS15 or IPV15 Sensor IPV0R Z
IPS06/IPVD6/IPSD6
Hot (Black)
Sensor
Neutral (White)
Line
120VAC, 60 Hz
(Black)
Black
LOAD
White
Red
Green Ground
Sensor
Black
Black
Hot (Black)
Neutral (White)
Use Terminal for 3-Way Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Line
120 VAC, 60Hz
Line
120 VAC, 60Hz
WH
RD
BK
Switch Remote Sensor
WH
YL/RD
BK
(unused)
WH
RD
3-Way
BK Hot (Black)
Neutral (White)
RD
(unused)
Green
Ground
Green
Ground
Green Ground
3-Way
White
White
LOAD
LOAD
Sensor
Black
Black
Hot (Black)
Neutral (White)
Use Terminal for 3-Way Applications Only.
For Single Pole Applications,
Do Not Remove This Label.
Line
120 VAC, 60Hz
Line
120 VAC, 60Hz
WH
RD
BK
Switch Remote Sensor
WH
YL/RD
BK
(unused)
WH
RD
3-Way
BK Hot (Black)
Neutral (White)
RD
(unused)
Green
Ground
Green
Ground
Green Ground
3-Way
White
White
LOAD
LOAD
IPS02/IPV02/IPS05/IPV05
IPS15/IPV15
**3-Way with IPV0R Remote Sensor