Instructions / Assembly

WHITE WIRE
HOT WIRE
LOAD
LINE
Black
White
Grounding connection
to box (if box has a
grounding terminal)
Wire Connector
LINEcablebrings
power to the AFCI
Electrical
Box
Yellow
sticker
remains
in place
to cover
the LOAD
terminals
Black
Black
White
White
WHITE WIRE
HOT WIRE
LOAD
LINE
LINEcablebrings
power to the AFCI
Electrical
Box
Wire
Connector
Grounding connection
to box (if box has a
grounding terminal)
For Side wire -
Loop clockwise 2/3 of the
way around screw
For Back wire -
Insert bare wire fully and
tighten terminal clamp on
conductorONLY
Wire
3/4" (1.9 cm)
7. Connect the wires (choose A or B)... only after reading other side completely
A: One Cable (2 or 3 wires) entering the box OR B: Two cables (4 or 6 wires) entering the box
OR
RESET
TEST
TEST
RESET
RESET
TEST
TEST
RESET
RESET
TEST
TEST
RESET
Connect the LINE cable wires to the LINE terminals:
• ThewhitewireconnectstotheWHITEterminal(Silver)
• TheblackwireconnectstotheHOTterminal(Brass)
Connect the LOAD cable wires to the LOAD terminals:
• RemovetheYELLOWstickertorevealtheLOADterminals
• ThewhitewireconnectstotheWHITEterminal(Silver)
• TheblackwireconnectstotheHOTterminal(Brass)
Connect the grounding wires (only if there is a grounding wire):
•
Connecta6-inchbarecopper(orGREEN)12or14AWGwiretothegroundingterminalonthe
AFCI. If the box has a grounding terminal, also connect a similar wire to the grounding terminal
onthebox.ConnecttheendsofthesewirestotheLINEorLOADcable'sbarecopper(or
GREEN)wireusingawireconnector.Ifthesewiresarealreadyinplace,checktheconnections.
Complete the installation:
• Foldthewiresintothebox,keepingthegroundingwireawayfromtheWHITEandHOT
terminals. Screw the receptacle to the box and attach the faceplate.
• Gotostep8.
Back Wire:
TROUBLESHOOTING
Turn the power OFF and check the wire connections against the appropriate wiring diagram in step 7A
or 7B. Make sure that there are no loose wires or loose connections. Start the test from the beginning
of step 8 if you rewired any connections to the AFCI.
© 2012 Leviton Mfg. Co., Inc. PK-93015-10-00-2A
Wire
5/8" (1.6 cm)
For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only)
1 800 405-5320 (Canada Only)
www.leviton.com
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials
and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at
its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co.,
Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for labor
for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened,
abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied
warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction,
the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure
to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
About Wire Connections:
Side Wire:
Connect the LINE cable wires to the LINE terminals:
• ThewhitewireconnectstotheWHITEterminal(Silver)
• TheblackwireconnectstotheHOTterminal(Brass)
Connect the grounding wire (only if there is a grounding wire):
• Foraboxwithnogroundingterminal(diagramnotshown):ConnecttheLINEcable'sbare
copper(orGREEN)wiredirectlytothegroundingterminalontheOutletBranchCircuitAFCI.
• Foraboxwithagroundingterminal(diagramshownabove):Connecta6-inchbarecopper
(orGREEN)12or14AWGwiretothegroundingterminalontheAFCI.Alsoconnecta
similar wire to the grounding terminal on the box. Connect the ends of these wires to the
LINEcable'sbarecopper(orGREEN)wireusingawireconnector.Ifthesewiresare
already in place, check the connections.
Complete the installation:
• Foldthewiresintothebox,keepingthegroundingwireawayfromtheWHITEandHOT
terminals. Screw the receptacle to the box and attach the faceplate.
• Gotostep8.
For Back wire -
Insert bare wire fully and
tighten terminal clamp on
conductorONLY
Wire
3/4" (1.9 cm)
Back Wire:
Wire
5/8" (1.6 cm)
For Side wire -
Loop clockwise 2/3 of the
way around screw
About Wire Connections:
Side Wire:
LOAD cable feeds
power to other
receptacle(s)
WHITE WIRE
HOT WIRE
LOAD
LINE
8. Test your work
Why perform this test?
• IfyoumiswiretheAFCIitmaynotmitigatetheeffectsofarcingfaultsdueto
unintentional arcing in a circuit.
• IfyoumistakenlyconnecttheLINEwirestotheLOADterminals,theAFCI
will not reset and will not provide power to either the AFCI receptacle face
or any receptacles fed from the AFCI.
Procedure:
(a)
This AFCI is shipped from the factory in the tripped condition and cannot
be reset until it is wired correctly and power is supplied to the device.
Plug a lamp or radio into the AFCI (and leave it plugged in). Turn the
powerONattheservicepanel.EnsurethattheAFCIisstillinthetripped
condition by pressing the TEST button. If the indicator light on the AFCI
receptaclefaceisONandthelamporradioisOFFgototheTroubleshooting
sectionbecauseLINEandLOADwiringconnectionshavebeenreversed.You
will not be able to RESET the AFCI in this condition.
(b) Press the RESET button fully.IfthelamporradioturnsONandthe
IndicatorLightturnsON,theAFCIhasbeeninstalledcorrectly.IftheAFCI
cannot be reset, go to the Troubleshooting section.
(c) If you installed your AFCI using step 7B press the TEST button, then plug
a lamp or radio into surrounding receptacles to see which one(s), in
addition to the AFCI, lost power when you pressed the TEST button. DO
NOTpluglifesavingdevicesintoanyofthereceptaclesthatlostpower.
Placea"AFCIPROTECTEDOUTLET"stickeroneveryreceptaclethat
lost power, then press the RESET button to reset the AFCI.
(d) Press the TEST button (then RESET button) every month to assure proper
operation. If the Indicator light does not go out and come back on or if the AFCI cannot be
reset, then it must be replaced.
FOR CANADA ONLY
For warranty information and/or product returns, residents of Canada should contact Leviton in writing at Leviton
Manufacturing of Canada Ltd to the attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire
(Quebec), Canada H9R 1E9 or by telephone at 1 800 405-5320.
General Information
ThisproductiscoveredbyUSPatentNos.6,040,967;6,088,205;
6,246,558;6,282,070;6,381,112;6,433,978;6,437,953;6,639,769;
6,646,838;6,657,834;6,788,173;6,864,766;6,944,001;7,336,458;
7,355,117;7,400,479;7,463,124;7,697,252;7,737,809;7,764,151;
7,820,909;7,868,719*;7,907,371;8,054,595;8,130,480and
correspondingforeignpatents(*appliesonlytoAFTR2).
All devices rated 20A feed-through
RatingsCat. No.
15A-125VAC,60Hz
Tamper Resistant Outlet Circuit AFCI
AFTR1
20A-125VAC,60Hz
Tamper Resistant Outlet Circuit AFCI
AFTR2
SmartlockPro is a Trademark of Leviton Manufacturing Co., Inc.
registeredintheUnitedStates,Canada,MexicoandChina.