Product Brochure

Features and Benefits
General
TEST and RESET buttons are readily accessible on the face of
the device
Trip threshold meets or exceeds UL requirements for tripping time on
ground faults and on both series and parallel arcs for optimal safety
Patented bridge contact design provides individual sets of
contacts for receptacle face and downstream receptacles;
no power will be delivered to receptacle face if improperly wired
(line-load reversed)
Improved immunity to high frequency noise reduces nuisance tripping
Superior resistance to electrical surges and over-voltages enhancing
reliability
Status Indicator Light provides simple, intuitive feedback on power
and protection status as well as indication of line/load reversal for
at-a-glance analysis
One-piece T-design trip latch mechanism provides ecient operation
TEST and RESET button colors match device face oering pleasing
aesthetic
Impact-resistant thermoplastic cover and body for durability
Expanded wiring options with nine back-wire holes (two for each line
and load connection plus one for ground with an internal clamp) for
easy installation
Silver alloy contacts
Compatible with all Decora
®
devices and wallplates for multi-gang
installation option; available in select popular colors
Packed with coordinating wallplate for a finished look
Patented Reset Lockout
As an additional safeguard, all Leviton AFCI/GFCI devices feature a
lockout function which prevents the device from being reset if any of
the following conditions exist:
- it is not functioning properly
- protection has been compromised
- line and load wires were reversed during installation
Tamper-Resistant
Tamper-resistant to comply with the latest NEC
®
requirements for
tamper-resistant receptacles in residences and childcare facilities
GFCI Self-Test
Engineered to meet the latest UL standard for auto-monitoring
(self-test); periodically conducts an automatic internal test to
confirm that GFCI protected power is available.
- Provides continuous ground fault protection – detects and trips on
actual ground fault even when self-test is being conducted
- On initial power up, tests the GFCI within 3 seconds
- Auto adapts and shifts to more frequent testing if potential problem
is detected
- Testing frequency regularly updates protection status
- Electronics are designed to minimize false triggers
Key Specifications
Amperage: 15 Amp and 20 Amp
Voltage: 125 Volt
Feed-through: 20 Amp protection
NEMA: 5-15R, 5-20R
Pole: 2
Wire: 3
Indicators: Reverse wiring/power/self-test status
Termination: Back & Side
Warranty: 2-Year Limited
Agency Standards and Compliance
Meets the latest UL and CSA requirements
UL Listed (File # E480630)
CSA Certified (File #LR-57811)
Specification Details
AC Horsepower
Ratings
Electrical
Specifications
Environmental
Specifications
Material
Specifications
Mechanical
Specifications
Standards and
Certifications
At Rated
Voltage:
1 HP
Dielectric
Voltage:
Withstands 1250VAC
per UL 1699A &
UL 943
Temperature Rise
at terminals:
Max 30°C after
250 cycles OL at
200 percent rated
current
Flammability:
Rated V-2 per UL94
Operating
Temperature:
-35°C to +66°C
Face Material:
Thermoplastic
Body Material:
Polycarbonate
Line Contacts:
Brass Double-Wipe .031
Thick*
Terminal Screws:
Plated Steel
Grounding:
Self-Ground Clip
Grounding Screw:
Plated Steel
Yoke:
Zinc-Plated Steel
Clamps:
Brass
Terminal ID:
Brass-Hot,
Green-Ground,
Silver-Neutral
Terminal:
14-10 AWG
Product ID:
Ratings are
permanently
marked on device
Wiring:
Use with copper or
copper-clad wire.
No aluminum wiring
NEMA:
WD-6
ANSI:
C-73
NOM
UL Fed Spec:
WC-596
UL 498, CSA C22.2
No. 42
UL 943, CSA C22.2
No. 144.1
UL 1699A
CSA Technical Info:
Letter No. M-02A