Drilling
Temperature change causes sheets to expand and contract. Any
resistance can cause sheet distortion. Always pre-drill holes to allow for
thermal movement, providing enough space for seasonal temperature
uctuation.
Use only new or sharply ground steel or carbide tipped drill bits.
Drill at a low speed. Support sheet underneath to avoid vibration.
Pre-drill holes 1/16” larger than the screw’s diameter.
Do not drill within 1-1.5 inches from the edge of the multiwall sheet.
Note: Before fastening, remove dust or debris from sheet surface with compressed air or a vacuum.
Fastening
Attach sheets to the purlins using fasteners recommended for your specic application. For proper point
fastening, at least a 1/2” neoprene bonded washers should be used with screws.
Forty-eight inch (48”) wide sheets should be fastened to supports at all four corners, and at
points 6 inches in from the edges of each purlin support.
Seventy-two inch (72”) wide sheets should be fastened in the same way, with an additional screw
in the center of each purlin support.
Drive fasteners perpendicular to the multiwall sheet.
Do not overtighten screws. Overtightened screws may cause sheet to dimple. A correctly
installed fastener will sit ush against the sheet.
Double check that all fasteners are properly secured.
Note: Fasteners should penetrate
the structure by at least one (1) inch.
Depending on the structural material
being used, a larger washer may be
needed. Washers distribute load to a
wider area and help protect the surface
of the sheet from being damaged.