Printer Service Manual

4026-0XX
Diagnostic Information 2-17
Exit Sensor Service Check
Fan Service Check
FRU Action
1
Engine Board Disconnect the exit sensor cable from the
engine board. Check for +4.5 V dc to +5.5 V dc
at CN8-1. If incorrect, replace the engine board.
2
Exit Sensor Be sure the exit sensor is snapped in place and
the cable is firmly connected.
3
Exit Sensor
Flag
Check the flag for damage and free movement
and replace as necessary. Be sure the exit sen-
sor spring is properly installed and not discon-
nected, damaged, or missing.
Reconnect the exit sensor cable and check the
voltage at CN8-3 on the engine board as you
press the exit sensor flag. The voltage should
change as the flag is moved in and out of the
sensor.Ifincorrect,replacetheexitsensor.
4
Exit Sensor
Cable
Check the continuity of the cable. If incorrect,
replace the exit sensor cable.
FRU Action
1
Engine Board Turn the printer power off. Disconnect CN11
on the engine board. Turn the printer on and
measure the voltage between CN11-1 and
CN11-2. The voltage should read approxi-
mately +24 V dc. If incorrect, replace the
engine board.
If correct, turn the printer off and connect
CN11. Monitor the voltage between ground
and CN11-1 (FAN*) immediately as you power
on the printer. The voltage should go from +24
V dc with the fan motor off to approximately 0
V dc when the motor turns on. If incorrect,
replace the fan motor and cable assembly.
2
Fan Motor/
Cable
Be sure the fan is properly installed if the fan
is noisy. If correct, replace the fan motor
assembly.