SMD-011-PMA210
A0110
(BTS)
Generated when temperature in BTS
is below the basic level, or sensor
and ACU are abnormal
Upon low temperature, check if
heater(Heating PAD) is normal, and
upon normal temperature, replace
sensor and ACU.
A0120
(BTS)
Generated when BTS is submerged
owing to natural disaster and other
reasons, or sensor and ACU are
abnormal
As it does not operate normally even
after water subsides, activate BTS
through ACU OFF/ON.
A0130
(BTS)
Generated right before BTS is
submerged owing to natural disaster
and other reason, or sensor and ACU
are abnormal.
As this alarm reports critical
situation of BTS, take necessary
measures, and replace sensor and
ACU if they are not actually
submerged.
A0140
(BTS)
Generated when fire occurs in BTS,
or sensor and ACU are abnormal.
When sensor and ACU are abnormal,
replace sensor and ACU.
A0150
(BTS)
Generated when humidity in BTS is
higher or lower than the basic level,
or sensor and ACU are abnormal.
When humidity is normal, replace
sensor and ACU.
A0160
(BTS)
Generated when the entrance of BTS
is open and closed, or sensor and
cable are abnormal.
If the entrance is not open, replace
sensor and cable.
A0170
(BTS)
Generated when side entrance of
BTS is open and closed, or sensor
and cable are abnormal.
If the entrance is not open, replace
sensor and cable.
A0200
(BTS)
Generated when ACU-I4 module is
abnormal.
After checking it is normally
positioned and power is normal,
replace ACU if normal.
A0210
(BTS)
Generated when cooling FAN of
LPA/HPA is abnormal
Check the power of FAN and replace
FAN when power is normal.
A0220
(BTS)
Generated when BTS FAN is
abnormal
Check the power of FAN and replace
FAN when power is normal.
A0300
(BTS)
Generated when initial power is
applied at a very low temperature
(below -5℃)
Release that at more than +5℃.
A0310
(BTS)
Generated when rectifier of BTS,
AC/DC(MDR30), AC, and power are
Generated when rectifier of BTS,
AC/DC(MDR30), AC, and power are