User's Manual

STAREX-IS BSM Manual
Page:757(877)
Issue:1.
0
SMD-011-PMA210
(BSC) Shelf is removed. and if fault occurs despite its
connection, replace ABID BOARD.
A6611
(BSC)
Generated when ABID Board of
ASMB Shelf is removed.
Check the status of ABID BOARD,
and if fault occurs despite its
connection, replace ABID BOARD.
A6620
(BSC) SAID Board of SLB Shelf is removed.
Check the status of SAID BOARD,
and if fault occurs despite its
connection, replace SAID BOARD.
A6630
(BSC)
When the other clock recept
encounters a problem while one side
of clock to clock cable of dual SMP
is normally received
Check corresponding cable status
and CCP status. If normal, replace
SMP board.
A6631
(BSC)
When the other clock recept
encounters a problem while one side
of clock to clock cable of dual SMP
is normally received
Check corresponding cable status
and CCP status. If normal, replace
SMP board.
A6640
(BSC)
Generated when SAID Board of VCB
Shelf is deleted.
Check if SAID BOARD is equipped,
and if a fault occurs despite its
connection, replace SAID BOARD.
A6650
(BSC)
When the other clock receipt
encounters a problem while one side
of clock to clock cable of dual VMP
is normally received
Check corresponding cable status
and CCP status. If normal, replace
SMP board.
A6651
(BSC)
When the other clock receipt
encounters a problem while one side
of clock to clock cable of dual VMP
is normally received
Check corresponding cable status
and CCP status. If normal, replace
SMP board.
A6900
(BSC)
Error of E1/T1 link connected to
ALPA (LOSS OF SYNC, REMOTE
ALARM INDICATION, ALARM
INDICATION SIGNAL, OUT OF
FRAME)
Check E1/T1 link cable and ALPA,
LICA, and if abnormal, replace that.
A6910
(BSC)
Error of STM-1 link connected to
ALPA (LOSS OF SYNC, REMOTE
ALARM INDICATION, ALARM
INDICATION SIGNAL, OUT OF
Check STM-1 link cable and ALPA,
LICA, and if abnormal, replace that.