User's Manual Part 2

STAREX-IS BSM Manual
Page:307(877)
Issue:1.
0
SMD-011-PMA210
4.3.5.16. LOCATION PARA Information Change
To change LOCATION PARA information, click CDM->Change_Parameter_
Information_2-> CHG-LOC-PARA on the Command Window in order. Input the value
to be changed in each field as shown below.
Command CHG-LOC-PARA :BSC=a ,BTS=b ,SECT=c [,ACT_T_FRM=d]
[,PUF_ST_SZ=e][,PUF_P_SZ=f] [,PUF_INTERVAL=g] [,PUF_I_PWR=h]
[,PUF_P_STEP=i] [,TOT_PUF_P=j] [,MAX_PWR_PUF=k];
Input CHG-LOC-PARA :BSC=0 ,BTS=0 ,SECT=ALPHA,ACT_T_FRM=ON;
Output
Fig. 4.3-116 LOCATION PARA Information Change