4.3.5.19. POWER CONTROL Parameter Information (2) Change
To change POWER CONTROL Parameter information (2), click CDM-
>Change_Parameter_ Information_2-> CHG-PWR2-CTRL on the Command Window in
order. Input the value to be changed in each field as shown below.
Command CHG-PWR2-CTRL :BSC=a ,BTS=b ,FER=c ,USE_REV_P=d
[,GAIN_1500=e]
[,GAIN_2700=f] [,GAIN_4800=g] [,GAIN_9600=h] [,GAIN_1800=i]
[,GAIN_3600=j] [,GAIN_7200=k] [,GAIN_14400=l]
[,NORM_9600_5MS=m];
Input CHG-PWR2-CTRL :BSC=0 ,BTS=0 ,FER=c ,USE_REV_P=USE_REV_P,
GAIN_1500=255;
Output
Fig. 4.3-119 POWER CONTROL Parameter Information (2) Change