User's Manual Part 2

STAREX-IS BSM Manual
Page:390(877)
Issue:1.
0
SMD-011-PMA210
Fig. 4.4-14 Result of ALPA Network UNBlock Command
4.4.3. Can Device Status Control
Table 4.4-3 DEVICE Status List
Status
Types
Definition
NORM Normal
ABN_D Abnormal Deletion (Even equipped to PLD, it is in the Status of Removal)
ABN_F Abnormal Fault(Status that normal operation is impossible due to fault in
Device)
(Test: As a result of DSP Chip Hardware Test, NOK occurs)
ABN_M Abnormal MMC Block
INIT Initial (Even equipped to PLD, a processor managing the corresponding
device does not operate normally until now)
AB_OB Abnormal Online Block (Based on judgment that a normal call is impossible
due to faults in other devices, the appropriate device is blocked)
IDLE Even if it is normal, call resources are not allocated (CE, VCE)
BUSY normal and call resources are allocated (CE, VCE)
N_EQP Status defined as Not Equipped to PLD
READY Even if not defined in PLD, Device is inserted
UNDEF Status that un-defined status is inserted
ABN_I Status being separated as H/W Reset
ABN_B BER Test Status by User
NOR_PB In case that call exists when CHC, Chip is blocked, it indicates the status that
awaits until a call is terminated
it indicates, the Status that waits for the call termination in order to perform