4.3.5.3. FACILITIES MANAGEMENT TIMER Change
To change FACILITIES MANAGEMENT TIMER, click CDM->Change_Parameter_
Information_2-> CHG-FAC-TIMER on the Command Window in order. Input the value
to be changed in each field as shown below.
Command CHG-FAC-TIMER :BSC=a [,T1=b] [,T2=c] [,T4=d] [,T5=e]
[,T6=f] [,T12=g] [,T13=h] [,T16=i] [,T309=j];
Input CHG-FAC-TIMER :BSC=0,T1=255;
Output
Fig. 4.3-103 Facilities Management Timer
Change Display