User's Manual Part 5

STAREX-IS BSM Manual
Page:487(877)
Issue:1.
0
SMD-011-PMA210
Fig. 4.6-29 Signaling Link Test
4.6.3.2. Signaling Terminal Test
Signaling Terminal Test consists of RA Loopback and SELF Loopback, and RA
Loopback performs Loopback in Rate Adaptation function, performing an activation of
Signaling Link. Depending upon the result, it performs inspection function on the
Signaling Terminal and Lookback performs Lookback to STPA receiving terminal,
providing inspection function of Status. A test should be successfully conductedto
Signaling Terminal where corresponding Signaling Terminal is not allocated to
Signaling Link before testing Signaling Terminal, so that normal test result can be
reported.
Command TEST-ST:BSC_ID=a, STID =b, TYPE=c;
a = BSC Number ( 00 ~ 11 )
b = Signalling Terminal ( 1 ~ 16 )
c = TYPE ( SELF, RA )
Input TEST-ST:BSC_ID = 1, STID =2, TYPE=SELF;
Output