User's Manual Part 3

STAREX-IS BSM Manual
Page:531(877)
Issue:1.
0
SMD-011-PMA210
c : Fault Code Number
Input INH-FLT-MSG:BSC=0,BTS=0,FN=1000;
Display
Fig. 4.8-12 Display Result of Inhibition/Allowance for Fault Message Display
4.8.2.4. Alarm Message Suppress Command
This command is used for the following cases: when previously checked alarm(by
the user) is generating and burden BSM; when suppressing the report for the alarm
message from subsystem in order to monitor other important message.
This is the command blocking the message itself for the unnecessary alarm contrary
to the command (INH-ALM-MSG) which inhibits the alarm message to be displayed on
the BSM console window.
Command SUP-ALM-MSG:[BSC=a],[BTS=b],[SRC_CODE=c];
a : BSC Number(0 ~ 11)
b : BTS Number(0 ~ 47)
c : Alarm Source Code Number(1 ~ 9999)
Input SUP-ALM-MSG:BSC=0,BTS=0,SRC_CODE=30001;
Display