4.8.3. Alarm/Fault Control
4.8.3.1. Allowance Command for Inhibited Alarm Message Display
This is the command to allow randomly inhibited alarm message for display by the user.
If any specific alarm code is not designated, all the inhibited alarm code for display in
the designated system is allowed.
Command ALW-ALM-MSG:[BSC=a],[BTS=b],[AN=c];
a : BSC Number(0 ~ 11)
b : BTS Number(0 ~ 47)
c : Alarm Code Number(0 ~ 9999)
Input ALW-ALM-MSG:BSC=0,AN=4600;
Display
Fig. 4.8-15 Display Result of Allowance for Alarm Message Display Inhibition
4.8.3.2. Allowance Command for Inhibited Audible Alarm
This is the command to allow inhibited audible alarm.
Command ALW-AUD-ALM