ENGLISH FRANÇAIS ESPAÑOL Installation Guide/User's Guide ZigBee Dongle Be sure to read the "Safety Precautions" before using the product. Keep this manual in a place where anyone who uses the product can see it. Please be careful when using this product and check it has not been altered in any way beyond its default state to prevent the occurrence of accidents ZigBee Dongle MFL71683201 Rev.01_112819 www.lg.com Copyright © 2019 LG Electronics Inc. All Rights Reserved.
ENGLISH TABLE OF CONTENTS Thank you for using our air conditioner featuring the ZigBee application.
Safety Precautions The following safety precautions are intended to prevent unforeseen hazards or damage in advance by using the product safely and correctly. ! WARNING Failure to observe these instructions could result in death or serious injury. ! CAUTION Failure to observe these instructions could result in personal injury or property damage. ! WARNING When installing • Please contact a service center or installation shop to install the product.
ENGLISH BEFORE USE OR INSTALLATION Precautions for ZigBee dongle Installation • It must be installed by a professional installer. • The ZigBee thermostat should be installed within 30 meters. It is recommended to be installed near the product. • Install in a place free from electromagnetic interference. It may cause malfunction of the product. • If there is a wall or obstacle between the ZigBee dongle and the ZigBee thermostat, communication issues may occur.
Components Installation Parts Name Quantity ZigBee Dongle 1 USB Cable (120 cm) 1 Installation Equipment Appearance Appearance Name Driver Usim pin (needle) Manual 1 Double-sided Tape 2 5 ENGLISH ZIGBEE DONGLE INSTALLATION
ENGLISH ZIGBEE DONGLE INSTALLATION Wall Mounted 1. Check if the indoor unit is turned off and the power of the outdoor unit is turned off. 2. Open the control box of the indoor unit. 3. Connect the USB cable to the indoor unit PCB (CN_WF). 4. Connect the ZigBee dongle to the USB cable. 5. Install the ZigBee dongle on the flat ceiling near the indoor unit or on the corner of the indoor unit panel. (Use the included doublesided tape to fix it in place.
4Way Ceiling Cassette 1. Check if the indoor unit is turned off and the power of the outdoor unit is turned off. 2. Open the control box of the indoor unit. 3. Connect the USB cable to the indoor unit PCB (CN_WF). 4. Connect the ZigBee dongle to the USB cable. 5. Install the ZigBee dongle on the flat ceiling near the indoor unit or on the corner of the indoor unit panel. (Use the included doublesided tape to fix it in place.
ENGLISH ZIGBEE DONGLE INSTALLATION Ceiling Concealed Duct 1. Check if the indoor unit is turned off and the power of the outdoor unit is turned off. 2. Open the control box of the indoor unit. 3. Connect the USB cable to the indoor unit PCB (CN_WF). 4. Connect the ZigBee dongle to the USB cable. 5. Attach the ZigBee dongle to the ceiling tile. (Use the included double-sided tape to fix it in place.
ZigBee thermostat Commissioning • Use the USIM pin to press and hold the button in the hole of the ZigBee dongle for 3 seconds. • The Blue LED of the ZigBee dongle blinks when commissioning start. • Start commissioning by pressing the commissioning button on the ZigBee thermostat. • After commissioning is completed, the Blue LED of the ZigBee dongle is turned on. Note • The ZigBee dongle only supports 2.4 GHz radio frequency. • The join and bind process is included in commissioning.
ENGLISH CHECKLIST BEFORE REPORTING FAILURE Checklist Before Reporting Failure Symptoms The air conditioner is not connected on the ZigBee thermostat. The ZigBee dongle is not completed on commissioning. 10 Checklist • Is the power of the air conditioner disconnected? Actions • Connect the power of the air conditioner. • Is the Blue LED of • Connect the power of ZigBee dongle turned the ZigBee thermostat.
Open source software notice information To obtain the source code under GPL, LGPL, MPL, and other open source licenses, that is contained in this product, please visit http://opensource.lge.com. In addition to the source code, all referred license terms, warranty disclaimers and copyright notices are available for download.
ENGLISH SPECIFICATIONS FCC Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
Industry Canada Statement This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions: (1) This device may not cause interference. (2) This device must accept any interference, including interference that may cause undesired operation of the device.